21
̶
GO-2400M-PMCL / GO-2400C-PMCL
Control without external triggers
When controlling the exposure time using specified exposure times
Configure the settings as follows.
Item
Setting value / selectable range
Trigger Selector (trigger operation)
Frame Start
Trigger Mode
Off
Exposure Mode
Timed (control via exposure time)
Exposure Time
Varies depending on the Tap Geometry and CL Pixel Clock
settings. *
1
Exposure Auto
Off, Continuous
* 1 Max. value = [Acquisition Frame Rate] - Max. exposure time value A (“Exposure times” (page 19))
1
Set [Exposure Mode] to [Timed].
([Timed] is the default setting.)
2
Specify the exposure time in [Exposure Time].
The setting value for the exposure time can only be changed when [Exposure Auto] is set to [Off].
If [Exposure Auto] is set to [Continuous], temporarily set it to [Off] before changing the [Exposure
Time].
3
Set [Trigger Mode] to [On].
4
If necessary, change the [Exposure Auto] setting.
When not controlling the exposure time
Configure the settings as follows.
Item
Setting value / selectable range
Exposure Mode
Off
The exposure will be performed with an exposure time equal to 1 / frame rate.
* The [Exposure Time] setting will be disabled, and the [Exposure Auto] function cannot be used.