61
̶
GO-2400M-PMCL / GO-2400C-PMCL
Function name
Access
type
Setting range
Min. value
Max. value
Default value
Description
Pulse Generator
Frequency (Hz)
R/W
70.810386 to 74250000
70.810386
74250000
4.8E+07
Set the maximum
count up value using
frequency.
This value is
calculated based on
the Pulse Generator
Length value.
Pulse Generator
Start Point
R/W
0 to 1048574
0
1048574
0
Set the start point for
the High interval
using clock value.
When the counter
reaches this value,
the output becomes
1.
Pulse Generator
Start Point (ms)
R/W
0 to 14.1222
0
14.1222
0
Set the start point for
the High interval
using ms.
When the counter
reaches this value,
the output becomes
1.
The setting range
varies depending on
the Clock Pre-Scaler
value.
Pulse Generator
End Point
R/W
1 to 1048575
1
1048575
1
Set the start point for
the Low interval using
clock value.
When the counter
reaches this value,
the output becomes
0.
Pulse Generator
End Point (ms)
R/W
0.000013468 to 14.1222
0.000013468
14.1222
1.35E-05
Set the start point for
the Low interval using
ms.
When the counter
reaches this value,
the output becomes
0.
The setting range
varies depending on
the Clock Pre-Scaler
value.
Pulse Generator
pulse-width (ms)
R/O
0 to 14.1222
—
—
1.35E-05
Display High interval
width for the pulse in
ms.
This is a calculation
of the time between
the Start Point and
End Point.
The setting range
varies depending on
the Clock Pre-Scaler
value.
Pulse Generator
Repeat Count
R/W
0 to 255
0
255
0
Set the repeat count
for the counter.
When this is set to 0,
the counter will be
free-running with
limitless repeating.
Pulse Generator
Clear Activation
R/W
Off [Off]
HighLevel [High Level]
LowLevel [Low Level]
RisingEdge [Rising Edge]
FallingEdge [Falling Edge]
—
—
0: Off
Set the clear signal
condition for the
count clear input of
the pulse generator.