38
̶
GO-2400M-PMCL / GO-2400C-PMCL
When [Exposure Mode] is [Off]
FVAL
X1
Sensor
Exposure
Exposure Active
X2
Exposure duration
Tap Geometry
CL Pixel Clock (MHz)
Exposure stop period [X1]
(usec)
Period From FVAL end to
Exposure end [min] [X2]
(usec)
Horizontal ROI
ALL
13/H Freq
1X2-1Y
(Full)
37.125
342
≥
167
74.25
171
≥
75
84.85
162
≥
69
1X3-1Y
(Full)
37.125
252
≥
121
74.25
114
≥
35
84.85
100
≥
45
1X4-1Y
(Full)
37.125
172
≥
80
74.25
86
≥
36
84.85
80
≥
37
1X8-1Y
(Full)
37.125
88
≥
37
74.25_8
63
≥
26
74.25_10
81
≥
36
84.85_8
63
≥
8.9
84.85_10
81
≥
36
When [Exposure Mode] is [Timed]
FVAL
X1
Sensor
Exposure
Exposure Active
Exposure duration