36
̶
GO-2400M-PMCL / GO-2400C-PMCL
Tap
Geometry
CL Pixel
Clock
(MHz)
Period From
Trigger start
edge to
Exposure start
[A] (usec)
Period from
Exposure
endTo FVAL
start [B] (usec)
Period FVAL
end to next
trigger start
[C] (usec)
Max Exposure
[msec]
Min Exposure
[usec]
Horizontal
ROI
ALL
Framerate
– 13/H Freq
3/H Freq
+ 22×0.013
1X2-1Y
(Full)
37.125
80
884
≥
89
7999.658
79
74.25
40
452
≥
37
7999.829
40
84.85
38
428
≥
34
7999.838
38
1X3-1Y
(Full)
37.125
60
654
≥
65
7999.748
59
74.25
27
300
≥
11
7999.886
27
84.85
24
263
≥
24
7999.900
24
1X4-1Y
(Full)
37.125
41
454
≥
37
7999.828
40
74.25
21
228
≥
18
7999.914
20
84.85
20
214
≥
17
7999.919
19
1X8-1Y
(Full)
37.125
22
232
≥
17
7999.912
21
74.25_8
16
168
≥
13
7999.937
15
74.25_10
20
214
≥
19
7999.919
19
84.85_8
15
167
≥
2.1
7999.937
15
84.85_10
20
214
≥
19
7999.919
19
Smallest input pulse width of trigger signal: 10 µS or more
■
When [Exposure Mode] is [Trigger Width]
Scanning range
Shortest period of trigger [ms], exposure condition: minimum
exposure time
1X2-1Y
1X3-1Y
1X4-1Y
1X8-1Y
84.85 MHz
8-bit
84.85 MHz
8-bit
84.85 MHz
8-bit
84.85 MHz
8-bit
Full
15670
9736
7836
6046
ROI 2/3 (Height = 810)
10618
6597
5310
4094
ROI 1/2 (Height = 608)
8104
5035
4053
3122
ROI 1/4 (Height = 304)
4321
2685
2161
1661
ROI 1/8 (Height = 152)
2429
1510
1216
930
Binning Full (968 × 608)*
15670
9736
7836
6046
* GO-2400M-PMCL only
Exposure and readout cannot overlap on the GO-2400-PMCL. The above table indicates the shortest
trigger periods for the shortest exposure times. By adding the value of the exposure time you are
using to the values in the table, you can determine the shortest trigger periods under your own usage
environment.