AM-800GE / AB-800GE
- 83 -
12.4.3. Specify the image size to be captured
Refer also to the chapter 7.2. AOI (Area of Interest).
The following parameters are required to specify the image size.
OFFSET
X:
Specify the starting position of the image in the horizontal
direction
Width:
Specify the width of the image
OFFSET Y:
Specify the starting line of the image
Height:
Specify the height of the image
In order to readout full pixels,
OFFSET X = 0
Width = Maximum number of pixels in the horizontal direction
OFFSET Y = 0
Height= Maximum number of pixels in the vertical direction
The above setting includes OB in both horizontal and vertical.