7.8.2 Horizontal timing
7.8.2.1 If the binning control is OFF or 2x1
1LVAL 1862clk = 38.79
μ
s 1clk=20.83ns
(Exposure start line
1LVAL 1982 clk = 41.30
μ
s)
Fig.27 Horizontal timing (Vertical binning OFF)
7.8.2.2 If the binning control is 1x2 or 2x2
1LVAL 2022clk = 42.13
μ
s 1clk=20.83ns
(Exposure starting line
1LVAL 2182 clk = 45.46
μ
s)
Fig.28 Horizontal timing (Vertical binning ON)
7.8.2.3 LVAL-LOW level period
1.
When waiting for a trigger signal or at the exposure start line, LVAL-LOW period
varies as shown in the following table.
Binning Control
LVAL-LOW period
LVAL cycle
Ordinary Exposure start
Ordinary
Exposure start
OFF, 2x1
186clk
306clk
1862ck 38.79 us 1982ck 41.30 us
1x2, 2x2
346clk
506clk
2022ck 42.13 us 2182ck 45.46 us