![JAI AM-800GE User Manual Download Page 34](http://html1.mh-extra.com/html/jai/am-800ge/am-800ge_user-manual_3225207034.webp)
AM-800GE / AB-800GE
- 31 -
Fig.29 LVAL-LOW period varies
2.
When the trigger control mode is set to ON and Overlap is set to Readout,
LVAL-LOW period is 1LVAL as the maximum.
Fig.30 LVAL-LOW period if Overlap is set to Readout
EEN
LVAL
Trigger
EEN
LVAL
The first occurrence after the exposure start line:
LVAL-LOW period varies
“186clk
⇒
306clk” (Binning Vertical=1, OFF, 2x1)
“346clk
⇒
506clk” (Binning Vertical=2, 1x2, 2x2)
Maximum 2 LVAL + LVAL Low period