![JAI AM-800GE User Manual Download Page 25](http://html1.mh-extra.com/html/jai/am-800ge/am-800ge_user-manual_3225207025.webp)
AM-800GE / AB-800GE
- 22 -
7.2.3 Frame rate calculation in the AOI mode
The frame rate in AOI mode depends on each setting of Offset, Height, Bit allocation
or Binning control. In the following formulas, the part labelled (
round down
) has its
decimal values rounded down.
7.2.3.1 Binning control
setting : off or 1x2
If Offset is less 4, Offset is regarded as 4.
start_area_num = ((OffsetY - 4)/4)
round down
) x 4
end_area_num = (((2471 – ( OffsetY -5))/4)
round down )
x 4
Frame line number
=
(start_area_num / 4) + (( 2471 – end_area_num) – start_ar 1) +
(end_area_num / 4) + 52
Frame rate (Hz)
= 1/ (Frame line number x 0.00003879 )
Setting examples
Area
Offset Height
Frame rate
(
fps
)
1/2
622
1236
Continuous
16.11
Timed (EPS)
(
Smearless OFF
)
Trigger Width
1/4
932
618
Continuous
22.71
Timed (EPS)
(Smearless OFF)
Trigger Width
1/8
1086
310
Continuous
28.51
Timed (EPS)
Trigger Width
7.2.3.2 Binning control setting : 2x1 or 2x2
If Offset is less 4, Offset is regarded as 4.
start_area_num = (((OffsetY x 2) – 8)/4)
round down
) x 4
end_area_num = (((2471 – (Height x 2) + (OffsetY x 2) -9))/4)
round down )
x 4
Frame line number
=
(start_area_num / 4) + ((( 2471 – end_area_num) – start_ar 1)/2) +
(end_area_num / 4) + 26
Frame rate (Hz)
= 1/ (Frame line number x 0.000042125 )
Summary of Contents for AM-800GE
Page 97: ...AM 800GE AB 800GE 94 b Image Format Control c Acquisition Control d Digital IO Control ...
Page 98: ...AM 800GE AB 800GE 95 e Counter And Timer Control f Event Control ...
Page 99: ...AM 800GE AB 800GE 96 ...
Page 100: ...AM 800GE AB 800GE 97 g Analog Control h LUT Control i Transport Layer Control ...
Page 101: ...AM 800GE AB 800GE 98 j User Set Control k Action Control l JAI Custom Control ...
Page 102: ...AM 800GE AB 800GE 99 ...