10.4. Timed-Pre-dump mode (so-called RCT) (JAI Custom)
Until the trigger is input, the camera operates continuously . At this moment, the
video signal, FVAL and LVAL are output but DVAL is not output. When the trigger is
input, the fast dump is activated to read out the electronic charge very quickly,
after which the accumulation and the readout are performed. This fast dump period
is 24.672ms. When the accumulated signal against the trigger is read out, FVAL ,
LVAL and DVAL are output too.
To use this mode;
Acquisition Mode
: Multi
Acquisition frame Count
: 2
Trigger selector
: Frame Start
Trigger mode
: ON
Exposure Mode
: Timed
Trigger option (JAI Custom Control)
: Pre Dump
In this mode, Trigger Overlap is automatically set to OFF.
Important notes on using this mode
The following table shows minimum trigger interval in Trigger Overlap=OFF.
accumulation mode
Full scan
3166L
2/3 Partial
2546L
1/2 Partial
2242L
1/4 Partial
1776L
1/8 Partial
1545L
The above figures are for pixel formats MONO8 or Bayer8.
Fig.46 Pre-dump mode timing
Trigger
CCD Exposure
Exposure Active
int-FVAL
int-DVAL
24.672ms
2L
Summary of Contents for AM-800GE
Page 97: ...AM 800GE AB 800GE 94 b Image Format Control c Acquisition Control d Digital IO Control ...
Page 98: ...AM 800GE AB 800GE 95 e Counter And Timer Control f Event Control ...
Page 99: ...AM 800GE AB 800GE 96 ...
Page 100: ...AM 800GE AB 800GE 97 g Analog Control h LUT Control i Transport Layer Control ...
Page 101: ...AM 800GE AB 800GE 98 j User Set Control k Action Control l JAI Custom Control ...
Page 102: ...AM 800GE AB 800GE 99 ...