Pro II: Analog Input Modules
Pro II-AIn-F-4/14 Rev. E
ADwin
72
ADwin-Pro II
Hardware, manual Dec. 2018
Fig. 55 – Pro-AIn-F-4/14-D Rev. E: Pin assignment differential
Fig. 56 – Pro II-AIn-F-4/14 Rev. E: Front panels
Programming
The module is comfortably programmed with
ADbasic
instructions. The
instructions are described in
ADbasic
online help and in the Pro II Software
manual.
The include file
ADwinPro_All.inc
contains instructions for the following
functions:
AIN
AIN
PE
AIN
AIN
2-pole LEMO female
connector; series 00
Multi-Contact,
type EGG
BNC
connector
AIN
AIN
1-pole LEMO
connector
D-Sub connector
ANALOG IN 1 (-)
ANALOG IN 2 (-)
ANALOG IN 3 (-)
ANALOG IN 4 (-)
ENABLE
B
AGND
EVENT, A
ANALOG IN 1 (+)
ANALOG IN 2 (+)
ANALOG IN 3 (+)
ANALOG IN 4 (+)
/ENABLE
/B
AGND
RESERVED
/EVENT, /A
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
RESERVED
RESERVED
AIN-F4/14
ANALOG
INPUT
AIN-F4/14
ANALOG
INPUT
1
2
3
4
AIN-F4/14
ANALOG
INPUT
1
2
3
4
AIN-F4/14
ANALOG
INPUT
1
2
3
4
Function
Instructions
Configure sequence control
P2_ADCF_Mode
Do a single conversion – com-
plete or step by step
P2_ADCF
P2_Start_Conv
,
P2_Wait_EOCF
P2_Read_ADCF
Read several values
P2_Read_ADCF32
,
P2_Read_ADCF4
P2_Read_ADCF4_Packed