ADwin-Pro II
Hardware, manual Dec. 2018
65
Pro II: Analog Input Modules
Pro II-AIn-8/18-8B Rev. E
ADwin
Fig. 48 – Pro II-AIn-8/18-8B Rev. E: Pin assignments
Fig. 49 – Pro II-AIn-8/18-8B Rev. E: Board and front panel
Programming
The module is comfortably programmed with
ADbasic
instructions. The
instructions are described in
ADbasic
online help and in the Pro II Software
manual.
The include file
ADwinPro_All.inc
contains instructions for the following
functions:
Inputs 8B 1…8
Inputs AIn 9…16
Excitation 1 (-)
Sensor 1 (-)
Excitation 2 (-)
Sensor 2 (-)
Excitation 3 (-)
Sensor 3 (-)
Excitation 4 (-)
Sensor 4 (-)
Excitation 5 (-)
Sensor 5 (-)
Excitation 6 (-)
Sensor 6 (-)
Excitation 7 (-)
Sensor 7 (-)
Excitation 8 (-)
Sensor 8 (-)
reserviert
EVENT (+)
Excitation 1 (+)
Sensor 1 (+)
Excitation 2 (+)
Sensor 2 (+)
Excitation 3 (+)
Sensor 3 (+)
Excitation 4 (+)
Sensor 4 (+)
Excitation 5 (+)
Sensor 5 (+)
Excitation 6 (+)
Sensor 6 (+)
Excitation 7 (+)
Sensor 7 (+)
Excitation 8 (+)
Sensor 8 (+)
EVENT (-)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
reserviert
Analoger Eingang 9 (-)
Analoger Eingang 10 (-)
Analoger Eingang 11 (-)
Analoger Eingang 12 (-)
Analoger Eingang 13 (-)
Analoger Eingang 14 (-)
Analoger Eingang 15 (-)
Analoger Eingang 16 (-)
AGND
reserviert
Analoger Eingang 9 (+)
Analoger Eingang 10 (+)
Analoger Eingang 11 (+)
Analoger Eingang 12 (+)
Analoger Eingang 13 (+)
Analoger Eingang 14 (+)
Analoger Eingang 15 (+)
Analoger Eingang 16 (+)
AGND
reserviert
AGND
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
reserviert
reserviert
19AD1002
DC/DC CONVERTER
IN 5V OUT ±15V / ±65mA
XC2S200
XILINX
®
OCX
40MHz
LM3940
3.3V
LM3937
2.5V
XC17
S200
101
101
101
8Bxx
DATAFORTH
®
XXXXXXXX X
XXXXXX
XXxXx
XX
8Bxx
DATAFORTH
®
XXXXXXXX X
XXXXXX
XXxXx
XX
8Bxx
DATAFORTH
®
XXXXXXXX X
XXXXXX
XXxXx
XX
8Bxx
DATAFORTH
®
XXXXXXXX X
XXXXXX
XXxXx
XX
8Bxx
DATAFORTH
®
XXXXXXXX X
XXXXXX
XXxXx
X
X
8Bxx
DATAFORTH
®
XXXXXXXX X
XXXXXX
XXxXx
X
X
8Bxx
DATAFORTH
®
XXXXXXXX X
XXXXXX
XXxXx
X
X
8Bxx
DATAFORTH
®
XXXXXXXX X
XXXXXX
XXxXx
X
X
HCPL-
2631
19AIN8B1002
1
2
3
4
9
10
11
12
5
6
7
8
13
14
15
16
24 12 5 +V
AIN-8/18-8B
8B 1...8
AIN 9...16
Function
Instructions
Do a single conversion – com-
plete or step by step
P2_ADC
,
P2_ADC24
P2_Set_Mux
,
P2_Start_Conv
P2_Wait_EOC
P2_Read_ADC
,
P2_Read_ADC24
Read value and start new con-
version
P2_Read_ADC_SConv
P2_Read_ADC_SConv24
Use sequence control
P2_Seq_Init
,
P2_Seq_Start
P2_Seq_Read
,
P2_Seq_Read24
P2_Seq_Read24_Packed
P2_Seq_Wait
Control input limits
P2_ADC_Read_Limit
P2_ADC_Set_Limit
Synchronize
P2_Sync_All
Use LED
P2_Check_LED
,
P2_Set_LED