Pro II: Digital-I/O Modules
Pro II-CNT-x Rev. E
ADwin
144
ADwin-Pro II
Hardware, manual Dec. 2018
Fig. 130 – Pro II-CNT-x Rev. E: Specification
1
Programming
Programming in ADbasic
The module is comfortably programmed with
ADbasic
instructions. The
instructions are described in
ADbasic
online help and in the Pro II Software
manual.
The include file
ADwinPro_All.inc
contains instructions for the following
functions:
Pro II-CNT-T
Input / output level
TTL logic
Event input
TTL logic
Isolation
none
Pro II-CNT-D
Input / output level
compatible to RS422/485 (5V differ-
ential, 120
Ω
bus termiinating resis-
tor)
Event input
1 differential
(singleded operation possible)
Clock frequency SSI deccoder (CLK) 6kHz … 12.5MHz
Isolation
none
Pro II-CNT-I
Input current
typ.3.5mA / max. 7.5mA
input voltage range
(selectable via jumpers)
0…5V
0 … 12V
0…24V
reliable switching threshold
for 0
(low)
0…0.8V
0…1.6V
0…3.2V
reliable switching threshold
for 1
(high)
4.5…5V
10…12V
20…24V
Input over-voltage
8V
16V
30V
Negative voltage
-5V for all ranges
Switching time
100ns
Isolation
42V channel-channel / channel-GND
1. A low/high signal will reliably be recognized in the indicated voltage ranges. But the switch-
ing process can also be effected outside these voltage ranges.
Function
Instructions
Configure counters
P2_Cnt_Enable
,
P2_Cnt_Mode
Use counters
P2_Cnt_Clear
,
P2_Cnt_Get_Status
P2_Cnt_Latch
P2_Cnt_Read
,
P2_Cnt_Read4
P2_Cnt_Read_Latch
P2_Cnt_Read_Latch4
Use PWM counters
P2_Cnt_PW_Enable
,
P2_Cnt_PW_Latch
P2_Cnt_Get_PW
,
P2_Cnt_Get_PW_HL
,
P2_Cnt_Read_Int_Register
Use SSI decoders
(CNT-D only)
P2_SSI_Mode
,
P2_SSI_Set_Bits
P2_SSI_Set_Clock
P2_SSI_Set_Delay
,
P2_SSI_Read
P2_SSI_Read2
P2_SSI_Start
,
P2_SSI_Status