background image

Installing the fixed glass panel 

 

(

9

) Arrange the compensator on the tub rim, in the position

shown.

The distance must be measured from the tub rim, not
from the wall.

(

part 2-3-4

) Check correct levelling and mark the fastening points,

drill and insert the screw anchors.

 

(

9, detail 5-6

) Apply silicone to the rear part of the

compensator (the part resting on the wall) and the part resting on
the tub.
(

part. 7

) Position the compensator again, check levelling and fix to

the wall.

 

(

10, detail 1

) Apply silicone to the base of the closing profile

of the fixed glass panel, as shown, and on the side guides of the
plastic cap; then insert the cap in the closing profile. Remove any
silicone in excess.

NOTE: 

according to the version, fit the right cap (RH) and the left

cap (LH).

 

(

10, detail 2-3

) Insert the upright of the fixed glass panel in

the compensator and, after having checked the correspondence
between the hole of the tube (D) and that of the glass panel (E), 

fix

it provisionally to the compensator.
Be careful when handling the glass panel not to damage the
plastic cap which you can just fitted.

 

(

11

Provisionally fix 

the glass panel to the tube.

Electric connections (where applicable)
and plumbing

 

(

12

) Arrange the following under the tub and through the

support joint:

a) bonding wire (from the mixing unit)

b) connection wire to the face plate (where applicable)

c) two feeding flexible hoses 

 

(

12, detail 2-3

) It is advisable to arrange the wire(s) first,

joining the ends with adhesive tape so make them slide easily and
to prevent them from getting jammed under the tub.
Then connect:

a) 

(

detail 5

the bonding wire to the terminal on the

framework.

b) 

(

detail 6

the wire on the face plate to the connector in the

electric wiring box (where applicable).

c) 

(

detail 7

the flexible hoses to the outlets on the floor.

Where applicable, connect the electric wiring box to the

mains and to the grounding system, according to the
wiring diagram and the indications shown in the “Electric
Safety” section.

Installing the door

 

(

13, detail 1-2-3

) After applying the plastic bushes (in the

indicated holes), and the spacers (2) position the door resting on
the column and 

provisionally fix it

.

 

(

13, detail 4

) Check closing of the door on the fixed glass

panel. Adjust the position if required by means of the screw which
fixes the glass panel to the distribution tube or alternatively by
slightly moving the fixed glass panel (

detail 5

).

Use a wooden block and a rubber hammer (on the door seal) to
make the two magnetic seals abut.

 

(

13, detail 7-8

) Definitively tighten the screws on the door

as those on the tube by applying the lid to the latter.

Shower crossbar assembly

 

(

14, detail 1-2

) Take the shower tube shown and fully fasten

the adjustment flange to one of the ends; fasten the shower tube
to the distribution tube fitting.
(

detail 3-4

) Take the shower tube to horizontal position and check

levelling; then arrange the ring nut cover on the wall and trace its
circumference (

detail 5

).

 

(

14, detail 6-7

) Lower the shower tube, loosen the ring nut

and position it in the middle of the traced circumference.
(

detail 8-9-10

) Mark the fastening points, insert the anchor screws

and fix the ring nut.

 

(

15, detail 1

) Take the shower tube back to the horizontal

position. 
(

detail 2-3

) Loosen the cap and make it abut against the ring nut;

then fasten the ring nut cover.

 

(

15, detail 4

) Fasten the showerhead making sure that its

wider diameter is parallel to the tube on which it is fixed.

Final fixing and sealing

 

(

16

) Fix the hand shower support to the door 

(the hole with the

larger diameter (G) must face upwards to allow correct positioning
of the hand shower)

; then connect the flexible hose, fastening the

hand shower to the other end, arranging the filter in between.

 

(

17

) Secure and fasten the column cover as shown; then

apply screws to the upper part of the column.

 

(

18, detail 1

) Definitive tighten the two screws of the fixed

glass panel. 
(

detail 2-3

) From inside the tub, from the bottom up, apply the seal

between the compensator and the glass panel upright, using the
specific tool; then cut the part in excess.

 

(

18, detail 4

) After having drilled the glass panel upright (use

the holes on the compensator as guide) and apply the screws shown.
(

detail 5

) Snap the cover on.

10

Summary of Contents for LINK 160x70

Page 1: ...NS KEEP FOR FUTURE REFERENCE Manuel d installation UTILISATION FONCTIONS ZONE DE DOUCHE CONSERVER SOIGNEUSEMENT Installationsanweisung BEDIENUNG DER DUSCHFUNKTIONEN SORGF LTIG AUFBEWAHREN Manual de in...

Page 2: ...INDICE INDEX SOMMAIRE NDICE INHALTSVERZEICHNIS Italiano 3 English 9 Fran ais 15 Deutsch 34 Espa ol 40 46...

Page 3: ...pra il bordo vasca mentre l anello metallico B va a contatto con la superficie sottostante 3 Posizionare la vasca nel luogo d installazione livellarla e regolarla in altezza ruotando manualmente i pie...

Page 4: ...ilitarne lo scorrimento ed evitare cos che possano impigliarsi sotto la vasca Collegare quindi a part 5 il cavetto equipotenziale al morsetto previsto sul telaio b part 6 il cavetto della mascherina a...

Page 5: ...e due viti autofilettanti ai tasselli N sotto il bordo vasca 22 Infilare le molle P sui puntelli agli angoli della vasca e farle scorrere verso l alto fino in battuta in modo che si dispongano all int...

Page 6: ...e la ghiera del devia tore G a met fra le due funzioni Se per esempio si vogliono utilizzare i getti dell idromassaggio verticale contemporaneamente alla doccetta si deve portare la ghiera tra i simbo...

Page 7: ...ressione e della portata rete idrica DIFFICOLT DI REGOLAZIONE DELLA TEMPERATURA MISCELAZIONE DELL ACQUA Verificare che i valori di pressione in rete all utilizzo tra acqua calda e fredda siano bilanci...

Page 8: ...cognitive o comunque prive delle nozioni necessa rie per il suo utilizzo Assicurarsi che i bambini nel caso utilizzino l apparec chiatura vengano sorvegliati da una persona respons abile della loro si...

Page 9: ...red from the edge of the rim must be at a height of 60 cm from the floor The feet allow adjustment in the range from 0 5 to 1 5 cm to compensate for differences in the floor level DO NOT LOOSEN THE LO...

Page 10: ...3 After applying the plastic bushes in the indicated holes and the spacers 2 position the door resting on the column and provisionally fix it 13 detail 4 Check closing of the door on the fixed glass...

Page 11: ...tub rim as possible dashed line in the figure Then adjust the height by means of the ring nut Y and adjust the distance with respect to the projection of the tub rim Then tighten the nut W 24 If you...

Page 12: ...me time Simply turn the dial of the diverter valve G mid way between the two functions For example if you want to use the vertical hydromassage jets and the hand shower at the same time turn the dial...

Page 13: ...contact a Jacuzzi Service Centre to have the water pressure and flow rate checked DIFFICULTY IN ADJUSTING WATER TEMPERATURE MIXING Check that the hot and cold water pressures are balanced Contact your...

Page 14: ...individuals children or anyone who has not been sufficiently instructed Children must be supervised by a person responsible for their safety Young Collection combinations are designed for domestic use...

Page 15: ...outchouc A doit tre plac sur le bord de la bai gnoire et l anneau m tallique B doit tre en contact avec la sur face inf rieure 3 Positionner la baignoire mettre niveau et r gler en hauteur en agissant...

Page 16: ...noire Brancher a d tail 5 le c ble quipotentiel la borne situ e sur le ch ssis b d tail 6 le c ble du panneau de commande au connecteur situ l int rieur du bo tier lectrique si pr vu c d tail 7 les tu...

Page 17: ...et les faire coulisser vers le haut jusqu en but e afin qu ils soient dispos s l int rieur du bord Introduire le circlips R dans la gorge correspondante de la tige 23 R gler les pattes Z comme indiqu...

Page 18: ...ent il suffit de placer la bague du d viateur G au centre des deux fonctions Par exemple pour utiliser les jets d hydromassage vertical en m me temps que la douchette placer la bague entre les symbole...

Page 19: ...our une v rification de la pression et du d bit du r seau hydrique DIFFICULTE DE REGLAGE DE LA TEMPERATURE MELANGE DE L EAU V rifier que les valeurs de pression du r seau l utilisation entre eau chaud...

Page 20: ...uites enfants compris ou n ayant pas connaissance des notions indispensables son utilisation S assurer que les enfants utilisant l appareil sont sous la surveillance d une personne responsable de leur...

Page 21: ...21 A Link dx 160 170 70 78 76 84 60 165 225...

Page 22: ...22 B Link sx 160 170 70 78 76 84 60 165 225...

Page 23: ...23 C C C 60 cm C1 C 90 4 mm max 8 mm max 90 A 2 5 mm max 7 5 mm max A B B 1 3 C 8 mm 6x40 mm G G 4 3 8 F 1 2 M 1 2 A B 2...

Page 24: ...24 T H E Y O U N G C O L L E C T I O N M4 T H E Y O U N G C O L L E C T I O N T H E Y O U N G C O L L E C T I O N 2 1 3 OK 5 1 2 OK OK A B C 3 4 6...

Page 25: ...25 1 4 2 3 5 7 8 6 OK 6 mm 3 9x32 mm 7 2 1 2 5 3 3 4 8...

Page 26: ...26 A B 6 mm 3 9x32 mm 4 3x9 mm A 66 cm 160x70 170x70 B 74 cm 170x78 3 5 7 5 5 4 2 1 6 9 3 5x9 5 mm 2 3 D E 1 DX SX 10...

Page 27: ...27 a c b 1 2 3 4 T H E YO U N G C O L L E C T I O N b a c 5 6 7 11 12...

Page 28: ...28 M5x16 mm 1 3 2 7 4 6 5 OK 5 5 5 7 8 13 1 2 3 4 5 6 7 8 9 OK 6 mm 10 3 9x32 mm 14...

Page 29: ...29 1 4 2 3 OK 15 1 G 2 M4x20 mm 16...

Page 30: ...30 1 3 2 3 9x19 mm M5x12 mm 17 CLICK 1 4 5 5 4 4 4 1 3 1 2 2 3 5x13 mm 3 mm 18...

Page 31: ...31 Hydro Jet Twist Jet 1 2 3 5 1 2 2 5 7 4 3 A LCOOL 6 19 20...

Page 32: ...32 2 a b c d a b d c a b d c a b d c a b d c 180 d a b c U L Z P 4 2x22 mm 1 2 L N 3 9x13 mm P R 21 22 2 2 1 1 1 1 483 mm X 1 10 mm n 2 17 mm X Y W Z 483 mm X Z 23 24...

Page 33: ...33 1 1 1 2 25...

Page 34: ...Die Gummidichtung A muss auf dem Wannenrand angebracht werden w hrend der Metallring B mit der darunter liegenden Fl che in Ber hrung sein muss 3 Die Wanne am Installationsort anbringen nivellieren u...

Page 35: ...der Verkleidung wo vorgesehen c die beiden Zuf hrungsschl uche 12 Teil 2 3 Wir empfehlen zuerst das die Kabel durchzuf hren und sie an den Enden mit Klebeband zu verbinden um ihren Verlauf zu erleich...

Page 36: ...den zwei selbst einschneidenden Schrauben an die D bel N unter dem Wannenrand befestigen 22 Die Federn P in die St tzen an den Ecken der Wanne einsetzen und nach oben bis zum Anschlag gleiten lassen d...

Page 37: ...enn gew nscht k nnen auch zwei Funktionen gleichzeitig verwendet werden Die Ringmutter des Umschalters G auf die Mitte zwischen den zwei Funktionen stellen Wenn zum Beispiel die Strahlen der vertikale...

Page 38: ...EICHENDEM DRUCK Die D sen reinigen Wenn dies nicht ausreichend ist mit dem Kundendienstcenter Jacuzzi zur Pr fung des Drucks und der F rdermenge des Wassernetzes Kontakt aufnehmen EINSTELLUNGSSCHWIERI...

Page 39: ...ngsf higkeiten und oder Sachkenntnissen ben tzt werden oder die keine notwendige Kenntnis ihrer Anwendung besitzen Sicherstellen dass Kinder bei der Anwendung der Einrichtung von einer f r ihre Sicher...

Page 40: ...se debe poner en contacto con la superficie que se encuentra debajo 3 Posicionar la ba era en el lugar de instalaci n nivelarla y regularla en altura girando manualmente las patas C ubicadas en los n...

Page 41: ...ncial al borne previsto en el armaz n b det 6 el cable del panel al conector situado dentro de la caja el ctrica donde est previsto c det 7 los tubos flexibles en las salidas del suelo Donde est previ...

Page 42: ...s ngulos de la ba era y hacerlos deslizar hacia arriba hasta el tope de manera que se dispongan dentro del borde Introducir el anillo R en la correspondiente ranura del puntal 23 Regular los soportes...

Page 43: ...es simult neamente basta posicionar la tuerca anular del desviador G en el medio entre las dos funciones Si por ejemplo se desea utilizar los chorros del hidromasaje vertical simult neamente con la du...

Page 44: ...si n del caudal de la red h drica DIFICULTADES DE REGULACI N DE LA TEMPERATURA MEZCLADO DEL AGUA Controlar que los valores de presi n en la red durante el uso entre agua caliente y fr a est n equilibr...

Page 45: ...toras sensitivas y o cognitivas reducidas o de cualquier manera sin las nociones necesarias para su uso Asegurarse de que los ni os en caso de que utilicen el equipo sean supervisados por una persona...

Page 46: ...23 4 2 5 1 Jacuzzi 12 2 2 2 1 2 3 8 F 1 2 M 30 1 2 F IEC 60335 1 A2 2006 600 6 2 2 4 A B 3 60 0 5 1 5 3 2 G 2 2 4 4 1 4 4 1 5 1 6 1 4 1 6 2 4 6 4 4 7 1 2 3 4 46...

Page 47: ...7 4 5 6 7 8 8 3 9 2 3 4 4 9 5 6 7 10 1 DX SX 10 2 3 D E 11 12 4 a b c 12 2 3 a 5 b 6 c 7 13 1 2 3 2 13 4 4 5 13 7 8 14 1 2 3 4 4 5 14 6 7 8 9 10 15 1 2 3 15 4 16 4 G 17 47...

Page 48: ...18 1 2 3 18 4 4 5 19 1 2 3 4 4 19 5 6 7 20 1 20 2 Twist Jet Hydro Jet Twist Jet Hydro Jet 20 3 21 L N 22 P R 23 Z Y W 24 P Z 24 L P U 25 1 4 25 2 JACUZZI EUROPE S p A 1 1 2 3 Jacuzzi Europe S p A 48...

Page 49: ...5 A B C Jacuzzi D 4 1 60 C G B C R 38 C 4 M 38 C P G D R G A B C D 38 P M G R 49...

Page 50: ...G D 4 M G 3 23 5 23 2 3 5 2 7 Jacuzzi 2 2 2 2 4 5 5 3 G R G M A B C D 50...

Page 51: ...1 T 2 3 4 V M C 5 H 6 L 4 Q 4 3 Young Collection 60 C 1 T R G 6 L Q H C M V 2 3 4 5 51...

Page 52: ...om Jacuzzi Bathroom Espa a SL Sociedad unipersonal A Company of Jacuzzi Brands Corp USA C Ausias Marc 157 159 Graner local 2 08013 Barcelona Espa a Tel 93 238 5031 Fax 93 238 5032 www jacuzzi eu spagn...

Reviews: