1. READ AND FOLLOW ALL INSTRUCTIONS.
2. A green colored terminal or a terminal marked G, Gr, Ground,
Grounding or the symbol* is located inside the supply terminal box
or compartment. To reduce the risk of electric shock, this terminal
must be connected to the grounding means provided in the electric
supply service panel with a continuous copper wire equivalent in size
to the circuit conductors that supply this equipment.
*IEC Publication 417, Symbol 5019.
3. At least two lugs marked “Bonding Lugs” are provided on the exter
-
nal surface or on the inside of the supply terminal box/compartment.
To reduce the risk of electric shock, connect the local common bond
-
ing grid in the area of the spa to these terminals with an insulated or
bare copper conductor not smaller than No. 6 AWG.
4. All field-installed metal components such as rails, ladders, drains or
other similar hardware within 10 feet (3m) of the spa shall be bonded
to the equipment grounding buss with copper conductors not smaller
than No. 6 AWG.
5. SAVE THESE INSTRUCTIONS.
WARNING:
Children should not use spas without adult supervision.
WARNING:
Do not use spas unless all suction guards are installed to
prevent body and hair entrapment.
WARNING:
People with infectious diseases should not use a spa.
WARNING:
To avoid injury, exercise care when entering or exiting the
spa.
WARNING:
Do not use drugs or alcohol before or during the use of a spa
to avoid unconsciousness and possible drowning.
WARNING:
Pregnant or possibly pregnant women should consult a phy-
sician before using a spa.
WARNING:
Water temperature in excess of 40°C (104°F) may be injuri
-
ous to your health.