Page 12
BLUE
BLUE
BROWN
BROWN
1
2
US/Canada J-460/J-465/J-470/J-480 Models:
240 VAC, 3-Wire Connection (60Hz)
Figure-D
TB1
All Export J-460/J-465/J-470/J-480 Models:
230 VAC, 3-Wire (50Hz)
to Circuit
Board
BLK
RED
Power In
RED
RED
BLK
BLK
1
2
Figure-C
TB1
to Circuit
Board
Power In
Green
TB3
Green
TB3
6.0 Power Requirements
Jacuzzi® spas are designed to provide optimum performance and
flexibility of use when connected to their maximum electrical service.
However, they are shipped factory configured for their most common
preferred electrical connection as follows:
•
All US/Canada 60Hz Models: 240VAC/50A
**
•
All Export 50Hz Models: 240VAC/30A**
If you prefer, your qualified technician can perform a minor circuit board
modification that allows the hot tub to operate on a different electrical
service (see table footnotes below).
US/Canada J-460/J-465/J-470/J-480 Models (60Hz)
Voltage:
240VAC
240VAC
240VAC
Max. Current Draw:
23A
36A
45A
Frequency:
60Hz
60Hz
60Hz
Number of Wires:
3
3
3
Circuit Breaker (2-Pole):
30A
*
50A
**
60A
***
*
In 30A configuration, the heater
will not o
p
erate
while either jets
pump is running.
**
In 50A configuration, the heater
will not o
p
erate
while both jets
pumps are running.
This is the factory setting.
***
In 60A configuration the heater
will o
p
erate
while both jets pumps
are running.