48
MAINTENANCE
WINTER STORAGE
In areas where temperatures drop to 0º or less, the water accumulated in the pump can freeze
and cause serious damage.
control valve
filter valve
pressure hose
ring
plastic cap (1)
primary valve (2)
filling position
tank
main filter
working position
pump
PROCEDURES
- Empty the tank completely by removing the drain plug.
- Remove the filter cover and open the filter valve.
- Remove the plastic cap (1) from the primary valve (2). Set the primary valve lever to the filling
position.
- Run the sprayer for about 30 seconds at half speed.
NOTE: To avoid damage to components do not run the pump over the recommended time.
- Then, set the primary valve lever back to the working position and reinstall the plastic cap (1).
- Repeat this operation at the end of eack working day during winter time to avoid problems in future
spray applications.
Summary of Contents for CONDOR B-12