MAINTENANCE
AGS SINGLE ANTIDRIP NOZZLE BODY
CONDOR: M-12/75 / S-12/75 / 800 B-12/75 / BX-12/75 / BX-12/75 MF)
Clean the nozzles and strainers daily or whenever necessary.
CONE NOZZLE
antidrip valve
nozzle body
lock
strainer
nozzle
(cone or flat fan)
nozzle cap
FLAT FAN NOZZLE
NOZZLE MAINTENANCE
After prolonged use, it may be necessary to
service the antidrip valve. Please refer to the
table below.
PROBLEMS
CORRECTIONS
CAUSES
1
nozzle
body
cup
filtering
element
cone
nozzle
nozzle
cap
filtering
element
flat fan
nozzle
nozzle
cap
Valve does not seal.
a - Improper tightening of nut (1).
b - Impurities on the diaphragm.
c
- Rupture of the diaphragm.
d - Rupture of the diaphram
followed by chemicals buildup.
a - Tighten the nut (1).
b - Remove and clean the diaphragm.
c - Replace the diaphragm.
d - Replace the diaphragm and clean
the cup.