System:
TT801
Corrective Maintenance
Sub-system:
Reference
: CM02
Page
: 1/2
Subject:
Replacing the Mains AC Fuse
Maintenance level:
2
Duration:
less than 10 minutes
Yellow “AC/DC” LED indicator does not light on when AC mains is connected to TT801
cabinet.
A flat blade screwdriver (6.5 X 150 mm)
A Mains AC fuse 5A- 250V (ref.: 5A HPC TDC)
Switch off the unit.
Unplug both cables (acoustic transducer and AC Mains).
Step Action
1.
Loosen the ten screws that fit the front panel on its case:
2.
Remove the front panel from the case:
3.
Using the flat blade screwdriver, remove the Mains AC fuse from its stand:
4.
Install the new fuse.
5.
Fit the front panel back in its case.
6.
Refit the ten screws to fit the front panel on the ABS casing.
7.
Connect AC mains power to TT801 cabinet.
The yellow AC/DC LED indicator lights on.
8.
End of procedure.