Remote Control System TT801 – User Guide
MU-TT801-AN rev.6 September 2009
45
TR
ANSMIT SETTINGS
TYPE : RT8xx
TRANSMIT TYPE :
IIF
FREQ : 12 kHz
RECURRENCE :
MANU
SCROLL = CHOICE
ENTER = VALID
Step 1
Step 2
Step 3
Step 4
RECEIVE SETTINGS
TURN AROUND TIME :
20 ms
CRF : MONO
11.0 kHz
RANGING :
DISTANCE
PRESSURE MEAS: ON
SCROLL = CHOICE
ENTER = VALID
Step 6
Step7
Step 8
Step 9
Figure 10 - Displays of Pressure Measurement Configuration
The pressure measurement can also be configured by saving a configuration. Refer to the
section III.4.4.1 to find the procedure to follow with the same specific parameters as
described above.
Note
If the automatic recurrence is selected for pressure measurement interrogations, it is
recommended to evaluate the total duration of the sequence before choosing the
period of recurrence.
Upon receipt of an IIF pulse, the beacon transmits two pulses at CRF frequency and the
TT801 displays:
TYPE : RT8xx
CMD : IIF / PRESSURE MEAS.
FREQ : 12.0 kHz
RECURRENCE : MANU
TURN AROUND TIME : 20 ms
MONO 11.0 kHz
DISTANCE
PRESSURE MEAS : 8 dBars
ENTER = TRANSMIT
Figure 11 - Display of measured pressure returned
Result