Remote Control System TT801 – User Guide
MU-TT801-AN rev.6 September 2009
41
Step Action
6.
Configure the
CAF
(or
FT0
for RT6xx series) receiver:
•
Choose the receive type (
MONO
or
MFSK
) using the SCROLL key then press
ENTER key to confirm
•
Choose the
frequency
(8 to 16 kHz) by using the
SCROLL
key or the numerical key
for the
MFSK code number
(0 to 23) of the CAF. Press
ENTER
key to confirm
if you have chosen
‘
R Pinger
’
(AR/RT8xx only)
or
‘
Pinger ON
’
function, you
also have to define the Pinger FRequency
PFR
(
FT4
for RT6xx):
•
Choose the receive type (
MONO
or
MFSK
) using the SCROLL key then press
ENTER key to confirm
Choose the
frequency
(8 to 16 kHz) by using the
SCROLL
key or the numerical key for
the
MFSK code number
(0 to 23) of the PRF. Press
ENTER
key to confirm
7.
Select the type of the information to display (
RANGING
):
DISTANCE
or Elapsed
TIME
using
SCROLL
key and press
ENTER
key to confirm.
Upon completion of the operation, TT801 displays the message “
STORAGE
COMPLETED
” and return to the
MAIN MENU
display.
8.
End of procedure.