Operation programming
The setting is made with the controller. The pump behaviour differs with each control mode.
Menu
Control mode/Function
Parameter
Default
Mode se
-
lection
-
MAN/EXT
MAN
External
control
Analog preset control 0 - 20mA/ 4 - 20mA/ 20 - 0mA/ 20 - 4mA
4-20mA
Analog variable con
-
trol
SP1 current 0.0 - 20.0mA
4.0mA
SP1 flow rate
0mL/H - 150L/H (D150)
0mL/H
0mL/H - 300L/H (D300)
0mL/H
SP2 current 0.0 - 20.0mA
20.0mA
SP2 flow rate
0mL/H - 150L/H (D150)
150L/H
0mL/H - 300L/H (D300)
300L/H
Pulse control*
0.01562mL/PLS - 300mL/PLS (D150)
0.01562mL/PLS
0.03125mL/PLS - 120mL/PLS (D300)
0.03125mL/PLS
Batch control*
15.62mL/PLS - 300L/PLS (D150)
15.62mL/PLS
31.25mL/PLS - 600L/PLS (D300)
31.25mL/PLS
Interval batch control*
0 - 9day, 0 - 23Hr, 1 - 59min
0D : 0H : 1M
15.62mL - 300L/PLS (D150)
15.62mL/PLS
31.25mL - 600L/PLS (D300)
31.25mL/PLS
Profibus control
Address : 1 - 126
50
Signal input
STOP
Closed = Pump OFF/ Closed = Pump ON
Closed = Pump OFF
PreSTOP
Closed = Pump OFF/ Closed = Pump ON
Closed = Pump OFF
Interlock
Closed = Pump OFF/ Closed = Pump ON
Closed = Pump OFF
Leak detection
Enable/ Disable
Enable
Alarm
OUT 1
Batch Complete/ STOP/ Pre-STOP/ Interlock/
Leak Detection/ Motor Overload/ Drive Error
Leak Detection: Enable
Other alarms: Disable
OUT 2
Volume Prop. PLS/ Batch Complete/ STOP/
Pre-STOP/ Interlock/ Leak Detection/ Motor
Overload/ Drive Error
Interlock: Enable
Other alarms: Disable
Analogue output
SP1 current 0.0 - 20.0mA
4.0mA
SP1 flow rate
0mL/H - 150L/H (D150)
0mL/H
0mL/H - 300L/H (D300)
0mL/H
SP2 current 0.0 - 20.0mA
20.0mA
SP2 flow rate
0mL/H - 150L/H (D150)
150L/H
0mL/H - 300L/H (D300)
300L/H
Others
Suction speed
100%/ 75%/ 50%/ 25%
100%
Maximum flow rate
200mL/H - 150L/H (D150)
150L/H
400mL/H - 300L/H (D300)
300L/H
AUX speed
200mL/H - 150L/H (D150)
150L/H
400mL/H - 300L/H (D300)
300L/H
Diaphragm position
MAX OUT Pos./ MAX IN Pos.
MAX OUT Pos.
Buffer
Enable/ Disable
Disable
Anti-Chattering
1msec/ 2msec/ 5msec
5msec
Output logic (OUT 1)
Normally Open/ Normally Close
Normally Open
Output logic (OUT 2)
Normally Open/ Normally Close
Normally Open
Unit
Litter/ US gallon
Litter
Keypad lock
00000 - 99999
00000
Language
English/Dutch/French/Danish/Spanish/German English