26
Installation
This section describes the installation of the pump, piping and wiring.
Read through this section before work.
Points to be observed
Observe the following points when installing the pump.
• Risk of electrical shock. Be sure to turn off power to stop the pump and related devices
before service is performed.
•
If you notice any abnormal or dangerous conditions, suspend operation immediately and
inspect/solve problems.
• Do not place explosive or flammable material near the pump.
• Use of a damaged pump could lead to an electric shock or death.
Pump mounting
Select an installation location and mount the pump.
Necessary tools
• Four M8 bolts (pump mounting)
• Adjustable wrench or spanner
Select a suitable place.
Always select a flat floor free of vibrations. See page 10 for detail.
Anchor the pump by four M8 bolts.
Be sure to fix the pump at four points.
NOTE
Select a level location, or the flow may reduce.
1
2
Pump mounting