33
In
stal
lat
ion
■ AUX IN/Analog OUT
To activate the AUX function or to use the analogue output, connect signal wires to the AUX terminal or the
4-20mA output terminal via the DIN 5-pin connection.
When using an open collector (for AUX IN):
Pay attention to polarity. AUX (3) is plus (+), and COM (4) is minus (-).
When using a no-voltage contact (for AUX IN):
Use a mechanical relay designed for an electronic circuit. Its minimum application load should be 5mA or less.
When using analogue output:
Pay attention to polarity. The 0-20mA (1) is minus (-) and 0-20mA (5) is plus (+). The max load resistance is 300Ω
.
1 : 0-20mA (Brown)
2 : N.C. (White)
3 : AUX (Blue)
4 : COM (Black)
5 : 0-20mA (Green)
*
Each wire is coloured as above for our optional cable.
■
Alarm OUT (DIN connector)
To transmit the signal to an external device, connect signal wires to the OUT terminal via the DIN 4-pin connection.
Alarm OUT 1 (OUT 1) <Mechanical relay>: Enable or disable the alarm outputs of batch completion,
STOP, Pre-STOP, interlock, motor overload (/drive error) and leak detection individually.
*Leak detection only is enabled at factory default setting.
Alarm OUT 2 (OUT 2) <PhotoMOS relay>: Enable or disable the alarm outputs of the volume propor-
tional pulse, batch completion, STOP, Pre-STOP, interlock, motor overload (/drive error) and leak
detection individually.
*Interlock only is enabled at factory default setting.
1 : Alarm OUT 1 (White)
2 : Alarm OUT 1 (Brown)
3 : Alarm OUT 2 (Black)
4 : Alarm OUT 2 (Blue)
*
Each wire is coloured as above for our optional cable.
Mounting direction of the output signal cable
Mount the DIN square connector cable in the following direction and secure it with a M3 screw.
1
2
3
4
Wiring
Output signal cable
M3 screw
Gasket
Alarm OUT terminal
Wiring for
AUX function
3
2
4
5
1
3
2
4
5
1
Wiring for
4-20mA output
Max.300Ω