COMPRESSOR LUBRICATION
(SEE FIGURE 1)

Add oil as required. The oil and oil filter
(if included) should be changed every
three months or after every 500 hours of
operation; whichever comes first. Only
pressure lubricated pumps have an oil
filter.  See Oil Capacity chart to
determine the recommended oil
quantities for your specific model.
Fill oil to specified level on dipstick or
sightglass.  Refer to owner’s manual for
further details.

AIR FILTER (SEE FIGURE 2)

Never run the compressor pump without
an intake air filter nor with a clogged
intake air filter. Use compressed air to

IN254500AV 11/99

BUILT TO LAST

TM

Two-Stage Air Compressor Pump
Maintenance Kits

© 1999 Campbell Hausfeld

Maintenance Instructions

For parts, product & service information

visit 

www.campbellhausfeld.com

Description

This maintenance kit is for use with
Campbell Hausfeld 5, 7

1

/

2

, 10 and 15 HP

two-stage air compressors.  This kit
includes two quarts of air compressor
oil and one air filter element.  Some
kits may include an oil filter that is for
use with pressure lubricated pumps
only.

Unpacking

When unpacking this kit, carefully
inspect for any damage that may have
occurred during transit. Verify all parts
are on hand before beginning repair.

General Safety Information

Disconnect, tag and
lock out power source
then release all pressure from the
system before attempting to install,
service, relocate or perform any
maintenance.

1. Read all manuals included

with this kit carefully
before beginning repairs.

2. Keep guards in good condition and

in place at all times.

3. Follow all local electrical and safety

codes, the National Electric Code
(NEC) and the Occupational Safety
and Health Act (OSHA).

4. Do not exceed the pressure limits

for any component in the system.

Maintenance

In order to maintain efficient
operation of the compressor system,
check the air filter and oil level before
each use.

MANUAL

blow the filter clean. Do not wash or oil 
the element. If it cannot be blown clean,
the filter must be replaced. Operating
compressor with a dirty filter can cause
high oil consumption and increase oil
contamination in the discharge air.
Use Figure 2 to determine the type of air
filter your model requires and how to
completely assemble the filter.

Make sure filter 

element is properly

seated in housing.  Poor fitting will
allow dirt to bypass the filter element
and damage the pump.

Oil Capacities

Models

HP

Quantities

CI05, CI07

5 or 7

1

/

2

2 qts.

CI10, CI15

10 or 15

4 qts.

HS

All

35 oz.

Full

Low

Figure 1 - Oil Fill Diagrams

Figure 2 - Filter Assemblies

Oil Fill Plug

Oil Drain
Plug

Dipstick
and Oil Fill

Drain On Side