Operational functions
■ Alarm output function (see page 47)
Enable or disable the output of the batch completion, STOP, Pre-STOP, interlock, diaphragm rupture detection,
pressure overload detection, and/or drive error detection functions which is preset to the Alarm OUT 1 and 2,
or the output of the volume proportional pulse preset only to the Alarm OUT 2. See page 33 "Alarm OUT (DIN
connector)" for wiring diagram.
Alarm OUT 1 (OUT 1) : Mechanical relay output (no voltage contact 1a×1 250VAC 3A, resistive load)
Alarm OUT 2 (OUT 2) : PhotoMOS relay output (no voltage contact 1a×1 24VAC/DC 0.1A, resistive load)
Other functions
■ Suction speed setting (see page 51)
Suction speed is adjustable by 4 levels depending on liquid property. Reduce suction speed so as to reduce
inertia resistance for the delivery of viscous liquid or to prevent cavitation for gaseous liquid. Select 100% (de
-
fault), 75%, 50% or 25%.
■ Maximum flow rate setting (see page 51)
The maximum allowable flow rate of the IX can be reduced if necessary. The default setting of the IX-D150 is
150L/H and the IX-D300 is 300L/H.
■ Diaphragm position adjustment (see page 51)
A pump shaft expands or contracts for easy diaphragm replacement. Select "MAX OUT Pos." through the
"Other Features" menu in order to extend the pump shaft to the maximum. Select "MAX IN Pos." to contract it
to the minimum and mount the pump head. See page 63 "Diaphragm replacement" for detail.
■ Anti chattering programming (see page 51)
Program a pulse recognition time for the IX not to be adversely affected by chattering or noise. Factory default
setting is 5 msec. This means the pump recognizes the pulse length of 5 msec or more. The other options are
1 and 2 msec and should be selected for the shorter pulse length, however, note the shorter the recognition
time is, the more susceptible to the interference of noise the pump becomes. Note the maximum allowable
input frequency of the IX is 100Hz.
■ Output logic setting (see page 51)
Select "normally open" or "normally closed" for the Alarm OUT 1 (OUT 1) and 2 (OUT 2) outputs.
■ Flow unit setting (see page 51)
Select L/H or GPH for the flow rate indication.
■ Language setting (see page 51)
Select your language through the language selection.
■ Keypad lock (see page 56)
The IX-D is shipped with the access codes at default values (00000). In order to prevent against unauthorized
tampering, you will need to change the access codes to your own values.
■ Default setting
Power on the pump while pressing the ESC key to recall default setting. Note the flow volume per shot ob
-
tained through the calibration process (see page 37) remains the same.