41
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
- 41 -
ROUTInE MAInTEnAnCE
FAULT
PoSSIBLE CAUSE
INTERVENTIoN
The appliance does not turn on.
•
The master switch is not
connected
•
The residual current device
or circuit breaker has tripped
•
Connect the master switch
•
Switch the residual current
device and/or circuit breaker
back on
Water does not reach the pasta
cooker tank.
•
The waterworks gate valve
is shut.
•
Open the waterworks gate
valve.
Water does not drain from the
cooking cavity.
•
The drain is clogged.
•
Clean the drain filter.
•
free the drain from residues.
The inner walls of the tank are
covered with limestone.
The water is too hard; the
softener is finished.
•
Connect the appliance to a
water softener.
•
Regenerate the water
softener.
•
Descale the cooking cavity.
The cooking cavity is stained.
•
Quality of the water
•
Ineffective detergent
•
Insufficient rinsing
•
filter the water (see water
softener)
•
Use the recommended
detergent
•
Rinse once again
The gas appliance does not turn
on.
•
Gas valve shut.
•
Air inside pipes.
•
Open the gas valve
•
Repeat the ignition
operations
The light indicators do not turn
on.
•
The master switch is not
connected
•
The residual current device
or circuit breaker has tripped
•
Connect the master switch
•
Switch the residual current
device and/or circuit breaker
back on
Troubleshooting
N.B.! Whenever the appliance does not work properly, try to solve the less serious
problems using this table.
N.B.! If the problem cannot be resolved, turn the appliance off and shut all the
supply valves. Then contact customer service.