For example: It is necessary to replace lost card (code number 12) by code 232002
with code settings reservation.
Press
[3] [#]
in engineer programming mode (red LEDs 1 and 2 blink synchro-
nously). Press
[1] [2] [#]
, panel indicates card code with buzzer and LED3 signals.
Press
[*]
(red LEDs 1-2 and green LED3 blink synchronously). Enter , panel
proceeds with current code settings' editing (red LED1 and yellow LED2 blink
alternately). Press
[#]
to move to upper menu level.
Next
[#]
button pressing switches the panel to main mode.
40 seconds pause between digits entry or cards passing causes panel switching to
main mode.
Code/card deletion
Press
[4] [#]
being in code parameters programming mode, then enter [code
[#]
or [code]+
[#]
. Code/card is deleted and the panel moves to upper
menu level.
Next
[#]
button pressing leads to exiting the programming mode.
After code/card deletion code number becomes vacant. When new code/card is registered
the smallest vacant number is chosen.
For example: It is necessary to delete code with 34 number.
Press
[4] [#]
in engineer code programming mode (red LEDs 1 and 2 blink synchro-
nously). Press
[3] [4] [#],
code is deleted and panel moves to upper menu level
(red LEDs 1 and 2 blink and LED3 is off).
Next
[#]
button pressing leads to exiting the programming mode (LED2 blinks red).
Resetting to factory defaults
Press
[5] [#]
being in code parameters programming mode then enter [engineer
code][#]. All settings are reset to factory defaults and the panel turns to the main
mode.
All previously programmed codes/cards, engineer and chief codes are programmed
according to factory settings by reset to factory defaults operation. In case of engineer
code loss turn to hardware reset to factory defaults section.
For example: It is necessary to carry out reset to factory defaults of the panel.
Press
[5] [#]
in engineer code programming mode (red LEDs 1 and 2 blink synchro-
nously), enter
[engineer code] [#]
, reset is executed, panel is in main mode (red
LED2 blinking).
Group card registration
Press
[10] [#]
in code parameters programming mode then pass all cards in turn for
registration. To exit group card registration mode and move to upper menu level
press
[#]
button.
After next
[#]
button pressing panel switches to the main mode.
The following parameters are set to all cards registered in this mode:
- point B access permission,
- outputs management prohibition,