28
Integrated Technical Vision Ltd
http://www.itvsystems.com.ua
Changing Code
Each user of 2 and 4 code category can change a code using
[*]
button command.
To change a code press
[*]
, buzzer utters three sound signals accompanied by
LEDs' flashes. Now introduce actual user code, then new user code and
[#]
twice.
New user code will be accepted if the present code type has permission for
code change, if actual code is correctly introduced, and if new code does not
coincide with already existing codes or duress codes.
To exit code change programming mode press
[#]
button.
You cannot change engineer or master code with the method described above.
For example:
[1] [2] [3] [4] [5] [6]
code user wants to change the code for
[6] [5]
[4] [3] [2] [1].
User should necessarily have code category 2 or 4.
Press
[*]
button, you will hear three long sound signals, LED2 starts to blink red.
Enter user old code
[1] [2] [3] [4] [5] [6] [#]
, long signal will be heard. In case of
false code entry or code category 1 or 3 an error signal will be heard. Enter new
code
[6] [5] [4] [3] [2] [1] [#]
, long signal confirms correct code entry. Enter new
code
[6] [5] [4] [3] [2] [1] [#]
repeatedly, long confirmatory signal will sound.
Press
[#],
long confirmatory sound and the panel switches to the main mode.
Switching Day/Night Modes
To switch day/night mode press
[1] [#]
(LED 2 blinks yellow), then enter user code
and press
[#]
.
Red LED 1 is switched on in night mode and switched off in day mode.
Programming the panel in stand-alone use