On the first and last panel in the drop line short S3, S4, S6 jumpers to add the
resistive load.
Take care of proper grounding of all panels in the network.
Setting control panel address
Panel address is set during programming (See "Control panel address programming"
section)
Outputs' types and attributes
You can set definite function, attribute, time and one of four operating conditions for
every output that is to fix their type, during programming. (See "Controller program-
ming").
PIN entry, card passing
PIN entry is carried out by consecutive keyboard buttons pushing. It should be
from four to ten figures length and is complete after
[#]
button pushing. Every
button pushing is accompanied by short built-in buzzer sound. If the entered PIN is
invalid - one long sound will be heard.
If invalid/not registered PIN or ID card is entered more than three times (this value
can be programmed) the keyboard will be blocked for time set in engineer code
programming mode. Keyboard blocking is signalled by red LED light.
Number of PIN matching attempts (from 0 to 255) is programmed using engineer
code. Number of attempts is not counted (see "Matching attempts number" section).
Door blocking time (from 0 to 255) is programmed using engineer code (see "Door
blocking time" part).
You can cancel mistaken code entering my means of
[*]
button.
During PIN entry 40 seconds interval cancels previous figures entering.
Proximity card (ID card) passing is equal to PIN entry. Controllers work with ASK
and FSK modulation cards.
Cardholders codes
There are several proximity card types used for controller management in
autonomous mode.
'00' card number is engineer code. All parameters are set using engineer code.
'01' card number is chief code. It allows
[0]
-
[4]
and
[10]
programming section
entering.
'02' - '999' code numbers are cardholders' codes.
By means of access codes/proximity cards people can:
- receive access grant;
- operate relay;
- change day and night modes.
Some information is programmed for every user individually. That is:
- access to each door grant/prohibition;
- programmed outputs operation;
- code category (1-4);
- day/night modes change permission.
Wiring