- no day/night switch permission,
- code category - 3.
The panel will indicate mistake at already existing card registration attempt.
Code matching attempts
Press
[1] [1] [#]
when been in code parameters programming mode, the panel
reflects current parameters settings by means of buzzer and LEDs.
[#]
button
pressing moves the panel to upper menu level. To set new parameters press
[*]
button and introduce number of attempts (from 0 to 10) and
[#]
. Factory default is 3.
For example: It is necessary to set code matching attempts number to 5.
In engineer code programming mode press
[1]
[1] [#]
(LED1 blinks red, buzzer and
LED3 indicate current code matching setting, then LED1 blinks red.) If current setting
differs from 5 press
[*]
(red LED1 and green LED2 blink synchronously). Press
[5]
[#]
, the panel moves to upper menu level (LEDs 1 and 2 blink red alternately, LED3 is
off). To switch the panel to main mode press
[#]
button (LED2 blinks red).
40 seconds pause between digits entry or cards passing causes panel switching to
main mode.
Keyboard lockout time
Press
[1] [2] [#]
when been in code parameters programming mode, the panel
reflects current parameters settings by means of buzzer and LEDs.
[#]
button
pressing moves the panel to upper menu level. To set new parameters press
[*]
button and introduce time (from 0 sec to 60 sec) and press
[#]
. Factory default is
40.
For example: It is necessary to set keyboard lockout time to 10 seconds.
When been in programming with engineer code mode press
[1]
[2] [#]
(LED1 blinks
red, buzzer and LED3 reflect current keyboard lockout time), then red LED1 blinks. If
current setting differs from 10, press
[*]
(red LED1 and green LED2 blink synchro-
nously). Press
[1]
[0] [#]
, the panel switches to upper menu level (LEDs 1 and 2
blink red alternately).
Next pressing of
[#]
button switches the panel to main mode (LED2 blinks red).
40 seconds pause between digits entry or cards passing causes panel switching to
main mode.
Door A time
Press
[1] [3] [#]
in code parameters programming mode, the panel reflects current
settings by means of buzzer and LEDs.
[#]
button pressing switches the panel to
upper menu level. To set new parameters press
[*]
button and enter time (from 0
sec to 255 sec) and press
[#]
. Factory default is 20.
The door will be open for unlimited time if you set time to 0 or 255 sec.
For example: It is necessary to set door A time to 30 seconds.
In engineer code programming mode (LEDs 1 and 2 blink red, LED3 is off) press
[1]
[3] [#]
(LED1 blinks red, buzzer and LED3 reflect current door A time, then LED1
blinks). If current setting differs from 30 press
[*]
(red LED1 and green LED2 blink
synchronously). Press
[3]
[0] [#]
the panel switches to upper menu level (LEDs 1
and 2 blink red alternately, LED3 is off).
Next pressing of [#] button switches the panel to main mode (LED2 blinks red).
Programming the panel in stand-alone use