http://www.itvsystems.com.ua
Integrated Technical Vision Ltd
11
Mounting
The controller is intended for inside mounting at 80% relative humidity.
When the panel is mounted on metal surface its reading distance decreases
Do not mount the panel or lay wires closely to the main power wiring and other sources
of electromagnetic interference
To mount the panel on the wall proceed as follows:
-
Release the screw in the lower part of the cover (Figure 3a)
-
Lift front cover slightly in the bottom part and pull it downwards (Figure 3b)
a)
b)
c)
d)
Figure 3. DLK642Lite mounting specifications.
- Disconnect X3 connector of built-in reader from panel PCB;
- Carefully release fixing tabs (Figure 3 c) then dismount PCB from panel base;
- Mark places for fixing holes using back plate as a template (Figure 3 d), then drill
with the 6 mm auger openings to depth of the concrete insert;
- Pull the wires
- Secure back plate with the screws
- Fix PCB on the back plate
- Connect the wires
- Connect PCB of the built-in reader to panel PCB
- Fasten front cover (Figure3a)
5...10mm
Fixing tabs
D1 D0 GN RD
Z1 GND + ER BZ
Z2 GND
Z3
Z4 GND
Z5
Z6 GND
A + B- GND + EB Z7 GND Z8
-PW R+
TM NC1 C1 NO1 NC2 C2 NO2 SA BEL
X 1
S3
S 4
S6
B A T
R S T
S 8
S 9
X 3
DL
K
64
2
V L1
X 2
X 2
S 5
Wiring
holes
Fixing holes
Mounting