16
Integrated Technical Vision Ltd
http://www.itvsystems.com.ua
Code category
Duress code
Every PIN user has additional duress code. Such code introduction leads to alarm
output engaging. When this code is entered, control panel grants access accord-
ingly to user code access level and options and moreover alarm output switches
on.
Cardholders using proximity cards do not have duress codes.
Duress code differs from PIN code to one in the last figure (e. g. If PIN code is '123456'
then duress code will be '123457'. If PIN code is '203409' then duress code will be '203400').
Alarm output switches off after actual code entry.
Alarm output
Alarm output will be engaged at every door sensor violation, except for door time
interval on conditions that door sensor is connected to the output.
Alarm output engages on programmed time - up to 255 seconds. Alarm output does
not switch on at '0' seconds value. Alarm output time is programmed with engineer
code.
LEDs
There are three LEDs on front plate of the controller. (See figure 1)
LEDs meanings in main mode are described below:
1. LED1 (red) indicates controller operating mode (day/night)
2. LED2 (red-green) indicates controller state: norm - red LED blinks, free access -
green and yellow LEDs blink in turn, keyboard lockout - red LED lights continuously.
Green LED lights continuously.
LEDs programming mode meanings:
1. LED1 (red) blinks the whole programming period
2. LED2 (red-green) indicates users' codes categories and parameters
3. LED3 (green) indicates users' codes categories and parameters and figurative
volumes of controller programming settings.
Door time
If door sensor is open, the corresponding access point goes into alarm. Alarm is not
invoked, if the contact is opened during Door Time interval. This interval starts when
access is granted and lasts for programmed time or terminates on opening and
subsequent closing of door sensor.
Door time is programmed using engineer code; it can be from 0 to 255 seconds.
Wiring
category
status
change permission
access schedule
1
not active
prohibited
---------
2
active
permitted
twenty-four-hour
3
active
prohibited
day
4
active
permitted
day