i-ALERT2 Application Guide
24 of 64
BETWEEN BEARINGS PUMP
On between bearings pumps, it is recommended to mount i-ALERT2 monitors to both bearing housings. If only one device is
to be installed on a pump, then it should be installed on the bearing housing that contains the thrust bearing. Note, that
this is not always the drive end bearing housing. Be sure to check the pumps cross sectional drawing to verify location of
the thrust bearing.
Figure 18: Double Suction , Horizontal Split case pump, mounted on thrust bearing housing
Figure 17: Between Bearings Pump (BB3), mounted on each bearing housing