1
2
3
4
5
1.
Adapter-to-backplate setscrew (222E, 6 in. S-group, 3 x 4-7, and 3 x 4-8G)
2.
Containment shell gasket (540N)
3.
Containment shell (750)
4.
Frame adapter (108)
5.
Adapter-to-backplate hex screw (370V)
11. Screw the three setscrews (222E for the 6 in. S-group, 3 x 4-7, and 3 x 4-8G pumps) or two connec-
tion screws (370V for M-group pumps) of the adapter (108) into the backplate and tighten.
This holds the containment shell in place.
12. Secure the casing (100) to the workbench with the suction flange facing downwards.
1
2
3
4
1.
Adapter-to-case hex screw (370)
2.
Frame adapter (108)
3.
Backplate-to-case gasket (351)
4.
Casing (100)
13. Insert the casing gasket (351) into the casing.
14. Insert the pre-assembled unit into the casing so that the crane hook of the adapter (108) faces the
center of the discharge nozzle.
15. Secure the adapter to the casing using hex screws (370) to the appropriate torque value.
See
6.5.5 Bolt torque values on page 75
6.5.4 Complete the pump reassembly
1.
Insert the gasket (360W) into the adapter. Check that all plugs, labyrinth seals and lip seals are in-
stalled.
6.5 Reassembly
74