NOTICE:
NOTICE:
Do not use this method to lift a Polyshield ANSI Combo with the pump and
motor mounted. These items are not designed to handle the heavy weight of
the Polyshield system. Doing so may result in equipment damage.
Figure 3: Example of a proper lifting method
2.3 Storage guidelines
2.3.1 Pump storage requirements
Storage requirements depend on the amount of time that you store the unit. The normal packaging is
designed only to protect the unit during shipping.
Length of time in storage
Storage requirements
Upon receipt/short-term (less than six
months)
•
Store in a covered and dry location.
•
Store the unit free from dirt and vibrations.
Long-term (more than six months)
•
Store in a covered and dry location.
•
Store the unit free from heat, dirt, and vibrations.
•
Rotate the shaft by hand several times at least every three months.
Treat bearing and machined surfaces so that they are well preserved. Refer to drive unit and coupling
manufacturers for their long-term storage procedures.
You can purchase long-term storage treatment with the initial unit order or you can purchase it and apply
it after the units are already in the field. Contact your local ITT sales representative.
2.3 Storage guidelines
Model 3296 EZMAG Installation, Operation, and Maintenance Manual