6
L
x
y
z
Fz
Mz
Fx
Mx
Fy
My
General technical data
Deflection f
max
is calculated using the mass moments of inertia of the profile.
The KLE is constructed from assemblies and cut-to-size elements and must be
checked for completeness prior to actual assembly.
If loads are combined, the general rule governing the total load also applies:
Assembly
KLE 6 60x60
KLE 8 80x80
Static load factor per Roller C
o
[N]
2,470
4,400
Dynamic load factor per Roller C [N]
4,400
7,800
Repeatability [mm]
± 0.1
± 0.1
V
max
[m/s]
10
10
Table 4 Technical data
Z
Y
KLE 6 60x60
KLE 8 80x80
I
y
44.32 cm
4
135.59 cm
4
I
z
57.46 cm
4
179.77 cm
4
l
t
7.23 cm
4
20.31 cm
4
W
y
13.08 cm
3
29.88 cm
3
W
z
19.15 cm
3
44.94 cm
3
Table 3 Profile data
|M
x
|
____
M
x max
+
|M
y
|
____
M
y max
+
|M
z
|
____
M
z max
+
|F
y
|
___
F
y max
+
|F
z
|
___
F
z max
≤ 1
KLE
M
x max
[Nm]
M
y max
[Nm]
M
z max
[Nm]
F
x max
[N]
F
y max
[N]
F
z max
[N]
6 60x60
25
50
100
500
750
500
8 80x80
50
100
150
1,500
1,500
1,000
Table 5 Simplified maximum load data for 10,000 km duty cycle