
Indicates that the selected List file in
Open
is exported to the USB flash
drive.
Run the List Program
You can select a List file to execute according to your needs, so that the power
supply outputs the corresponding waveform sequence. Take the List file in
Internal
as an example. The steps are as follows:
1. Press the composite keys
[Shift]+[I-set]
(Function) on the front panel to en-
ter the function menu.
2. Select
1. LIST: Off
and press
[Enter]
.
3. Press the Left/Right key to select
Open
and press
[Enter]
.
4. Press the Left/Right key to select
Internal
and press
[Enter]
.
5. Set the name of the List file to be recalled (that is, the file name set in
Edit
),
and press
[Enter]
.
The interface returns to the main interface of the LIST function, which is dis-
played as follows:
FUNCTION
LIST
Run Edit Open Export
6. Press the Left/Right key to select
Run
and press
[Enter]
.
At this point, the interface returns to the main interface of the system and
LIST RUN
is displayed in the lower right corner.
7. Turn on the
[On/Off]
.
8. Based on the selected trigger method, perform the trigger operation.
Take the manual trigger as an example. Press
[Shift]+[On/Off]
(Trigger) on
the front panel to run the selected List file. For details about the List trigger
method, see
6.8 Select Trigger Source (Trig Source)
.
•
The system will adjust the working mode of the power supply according to
the CC or CV priority mode set in the List file. For example, if the current
power supply is in the CV priority mode, and the list file to be run is set to the
CC priority mode, then the power supply will work in the CC priority mode
after the List file is triggered to run.
•
After the List file finishes running, the system determines whether to return
to the working mode before the List is run according to the
Normal
or
Last
option you selected.
Stop Running the List Program
When the List program is running, if you need to stop running, you can do the
following: Press the composite keys
[Shift]+[I-set]
(Function) on the front panel
to enter the function menu.
Copyright © Itech Electronic Co., Ltd.
76
Summary of Contents for IT6000B Series
Page 130: ...Power Supply Function E 02 The waveform is as follows Copyright Itech Electronic Co Ltd 118...
Page 132: ...Power Supply Function E 06A The waveform is as follows Copyright Itech Electronic Co Ltd 120...
Page 136: ...Power Supply Function E 16 The waveform is as follows Copyright Itech Electronic Co Ltd 124...
Page 137: ...Power Supply Function E 18 The waveform is as follows Copyright Itech Electronic Co Ltd 125...
Page 150: ...Power Supply Function Copyright Itech Electronic Co Ltd 138...