Parameter
IT6005B-80-150
Dimension ( mm)
483mm(W)*801.61mm(D)*151.3mm(H)
Weight( net)
20KG
Note:
1. The instrument needs to be customized under other AC input voltage ranges. For models
equipped with an emergency stop module (including AC contactor), the AC input voltage range
can only be: 342V
~
528V
Load Mode:
Parameter
IT6005B-80-150
Rated value ( 0
℃
-50
℃
)
Input voltage
0
~
80V
Input current
0
~
150A
Input power
0
~
5kW
Input resistance
0.001
~
7500
Ω
Min. operating
voltage
0.45V at 150A
Setup Resolution
Voltage
0.001V
Current
0.01A
Power
0.001kW
Resistance
0.001
Ω
Read Back
Resolution
Voltage
0.001V
Current
0.01A
Power
0.001kW
Resistance
0.001
Ω
Setup Accuracy
(within 12 months,
25
℃
±5
℃
) ±(
%
oOffset)
Voltage
≤0.02% + 0.02%FS
Current
≤0.1% + 0.1%FS
Power
≤0.5% + 0.5%FS
Resistance
≤1% + 1%FS
Read Back Accu-
racy (within 12
months, 25
℃
±5
℃
)
±(
%
of Output
+Offset)
Voltage
≤0.02% + 0.02%FS
Current
≤0.1% + 0.1%FS
Power
≤0.5% + 0.5%FS
Resistance
≤1% + 1%FS
Setup Temperature
Coefficient ±(
%
of
Output/
℃
+Offset)
Voltage
≤50PPM/
℃
Current
≤200PPM/
℃
Copyright © Itech Electronic Co., Ltd.
229
Summary of Contents for IT6000B Series
Page 130: ...Power Supply Function E 02 The waveform is as follows Copyright Itech Electronic Co Ltd 118...
Page 132: ...Power Supply Function E 06A The waveform is as follows Copyright Itech Electronic Co Ltd 120...
Page 136: ...Power Supply Function E 16 The waveform is as follows Copyright Itech Electronic Co Ltd 124...
Page 137: ...Power Supply Function E 18 The waveform is as follows Copyright Itech Electronic Co Ltd 125...
Page 150: ...Power Supply Function Copyright Itech Electronic Co Ltd 138...