
6.11.2 IO–2. Ps, Not-Invert
Parameter Description
IO–2. Ps, Not-
Invert
Parameter setting for pin 2.
Not-
Invert
Indicates whether to invert the input/output
pulse or level signal.
•
Invert: Yes
•
Not-Invert: No
Invert
Ps
This default function means the output
level from pin 2, which displays that
whether the instrument is under pro-
tection or not.
Input
Pin 2 receives the level signal from
the outside.
Output
Pin 2 sends the digital signal (1, 0,
PWM) to the outside.
True
By default (
Not-Invert
), the
output digital signal is 1 (i.e.
low level), and in the case of
Invert
, the output is high
level.
False
By default (
Not-Invert
), the
output digital signal is 0 (i.e.
high level), and in the case of
Invert
, the output is low level.
PWM
Digital signal of PWM.
PWM Freq
Frequency
PWM Duty
Duty cycle
How to Use
When pin 2 is set to default
Ps
function, pin 2 will output high or low level based
on whether the instrument is under protection or not. Under normal conditions
(Not under protection), and when pin 2 is under default setting (
Not-Invert
), pin
Copyright © Itech Electronic Co., Ltd.
192
Summary of Contents for IT6000B Series
Page 130: ...Power Supply Function E 02 The waveform is as follows Copyright Itech Electronic Co Ltd 118...
Page 132: ...Power Supply Function E 06A The waveform is as follows Copyright Itech Electronic Co Ltd 120...
Page 136: ...Power Supply Function E 16 The waveform is as follows Copyright Itech Electronic Co Ltd 124...
Page 137: ...Power Supply Function E 18 The waveform is as follows Copyright Itech Electronic Co Ltd 125...
Page 150: ...Power Supply Function Copyright Itech Electronic Co Ltd 138...