Parameter
IT6006B-500-40
Dimension ( mm)
483mm(W)*801.61mm(D)*151.3mm(H)
Weight( net)
20KG
Note: 1. The instrument needs to be customized under other AC input voltage ranges. For mod-
els equipped with an emergency stop module (including AC contactor), the AC input voltage
range can only be: 342V
~
528V
Load Mode:
Parameter
IT6006B-500-40
Rated value ( 0
℃
-50
℃
)
Input voltage
0
~
500V
Input current
0
~
40A
Input power
0
~
6kW
Input resistance
0.001
~
7500
Ω
Min. operating
voltage
2.4V at 40A
Setup Resolution
Voltage
0.01V
Current
0.001A
Power
0.001kW
Resistance
0.001
Ω
Read Back
Resolution
Voltage
0.01V
Current
0.001A
Power
0.001kW
Resistance
0.001
Ω
Setup Accuracy
(within 12 months,
25
℃
±5
℃
) ±(
%
oOffset)
Voltage
≤0.02% + 0.02%FS
Current
≤0.1% + 0.1%FS
Power
≤0.5% + 0.5%FS
Resistance
≤1% + 1%FS
Read Back Accu-
racy (within 12
months, 25
℃
±5
℃
)
±(
%
of Output
+Offset)
Voltage
≤0.02% + 0.02%FS
Current
≤0.1% + 0.1%FS
Power
≤0.5% + 0.5%FS
Resistance
≤1% + 1%FS
Setup Temperature
Coefficient ±(
%
of
Output/
℃
+Offset)
Voltage
≤50PPM/
℃
Current
≤200PPM/
℃
Read Back Temper-
ature Coefficient
Voltage
≤50PPM/
℃
Current
≤200PPM/
℃
Copyright © Itech Electronic Co., Ltd.
255
Summary of Contents for IT6000B Series
Page 130: ...Power Supply Function E 02 The waveform is as follows Copyright Itech Electronic Co Ltd 118...
Page 132: ...Power Supply Function E 06A The waveform is as follows Copyright Itech Electronic Co Ltd 120...
Page 136: ...Power Supply Function E 16 The waveform is as follows Copyright Itech Electronic Co Ltd 124...
Page 137: ...Power Supply Function E 18 The waveform is as follows Copyright Itech Electronic Co Ltd 125...
Page 150: ...Power Supply Function Copyright Itech Electronic Co Ltd 138...