Parameter
IT6018C-300-225
Maximum Input Ap-
parent Power
19.8kVA
Frequency
47Hz
~
63Hz
Setup Stability-30min
Voltage
≤0.02%+0.02%FS
±(
%
of Offset)
Current
≤0.1% + 0.1%FS
Setup stability-8h
Voltage
≤0.02%+0.02%FS
±(
%
of Offset)
Current
≤0.1% + 0.1%FS
Readback Stability-30min
Voltage
≤0.02%+0.02%FS
±(
%
of Offset)
Current
≤0.1% + 0.1%FS
Readback stability-8h
Voltage
≤0.02%+0.02%FS
±(
%
of Offset)
Current
≤0.1% + 0.1%FS
Efficiency
~
92%
Remote Sense Compensa-
tion Voltage
≤5V
Command Response Time
2mS
Power Factor
0.99
Storage Temperature
-10
℃~
70
℃
Protective Function
OVP, OCP, OPP, UVP, UCP, OTP, Vsense protection
Standard Interface
Standard: USB, CAN, LAN, VCP; optional: GPIB, analog card
(includes RS232), fiber optic socket
Isolation ( output to ground)
1000V
Working Temperature
0
~
50
℃
Dimension ( mm)
483mm(W)*801.61mm(D)*151.3mm(H)
Weight( net)
40KG
Note:
1. The instrument needs to be customized under other AC input voltage ranges. For models
equipped with an emergency stop module (including AC contactor), the AC input voltage range
can only be: 342V
~
528V
Load Mode:
Parameter
IT6018B-300-225
Rated value ( 0
℃
-50
℃
)
Input voltage
0
~
300V
Input current
0
~
225A
Input power
0
~
18kW
Copyright © Itech Electronic Co., Ltd.
250
Summary of Contents for IT6000B Series
Page 130: ...Power Supply Function E 02 The waveform is as follows Copyright Itech Electronic Co Ltd 118...
Page 132: ...Power Supply Function E 06A The waveform is as follows Copyright Itech Electronic Co Ltd 120...
Page 136: ...Power Supply Function E 16 The waveform is as follows Copyright Itech Electronic Co Ltd 124...
Page 137: ...Power Supply Function E 18 The waveform is as follows Copyright Itech Electronic Co Ltd 125...
Page 150: ...Power Supply Function Copyright Itech Electronic Co Ltd 138...