Replacing the safety thermostat (manual resetting)
Follow the instructions below to remove and refit the
thermostat:
- remove the thermostat retention bracket (1) by loo-
sening the screw (2).
- disconnect the power connectors from the Safety
thermostat (3).
- refit the thermostat unit in reverse fitting sequence;
The safety thermostat trips if the convection fan is
not working properly or anomalous overheating
occurs and/or the outflowing air temperature reaches
over 107°C, disengaging the burner, closing the gas
valve and stopping the appliance.
In case of part replacement (electronic boards, val-
ves, thermostats, pressure switches, fans, etc.), only
use the Manufacturer's Original Spares.
Replacing the SIT gas valve coils
The coil unit (1) cannot be replaced.
In case of a fault, the entire gas valve unit
will have to be replaced.
2
1
3
1
34
CUSTOMER SERVICE