CASE C – Fitting the pipes recessed in the floor
of the environment to be heated
This solution can be adopted in the event of wan-
ting/having to recess the fume exhaust pipe in the
floor while combustion air extraction occurs directly
inside the environment.
Installing the fume exhaust pipe:
- fit a 90° curve (cast aluminium) in the adapter con-
nection on the fume exhaust hole.
- add a short straight section of pipe to reach the
opposite side of the appliance.
- continue downwards with a second 90° curve (alu-
minium), laying the pipe inside the structure through
the specific openings.
- on arriving at the bottom of the appliance, continue
in the desired direction.
- check the correctness and the length of the
path described by the exhaust pipe to be reces-
sed in the floor and wall.
- make the pipe seats.
Before closing the pipes in the wall, insula-
te the fume exhaust pipe using material resi-
stant to temperatures above 200 °C (eg.
HT/Armaflex).
Chimneypot assemblage
To assemble the chimneypot on the unloaded intake
tubes use the clamp (1) and the (2) safety screw.
The chimneypot application has to satisfy the fol-
lowing requirement.
-The top of the exhaust fume tube has to be out of
the ebb zone, to avoid the eventual pressures that
will prevent the free exhaust product of the combu-
stion in the atmosphere.
-The chimneypot has to be placed right on top of the
tube in the proper way, if it
ʼ
s not placed in the proper
way, the fumes will get inside the tubes, and if this
happen it will cause problems to the appliance.
DIAPHRAGMS ASSEMBLAGE
The proper function of the appliance has to be cou-
ple to the tube Ø 54 mm it foresees the application of
the diaphragm (1) supplied with the apparatus equip-
ment.
The diaphragm has to be inserted inside the air intake
(2) and unloaded fumes (3) before assembling the ter-
minal.
Approach the apparatus, inserting the unloaded
/intake fumes curves in the right adapter connection
tubes.
To fasten the tubes use grease and be sure that
the O Rings are in their seating.
Check the work done.
2
+25mm
Ø 54
3
1
C
23
INSTALLER
2
1
Summary of Contents for faro
Page 1: ......