14
INSTALLER
Installation stage
The appliance installations stages are:
- Apparatus choice location
- Tube installation
- Parallel tube kit Ø 54 mm with unique terminal
- Separated pip kit Ø 54 mm with single terminal
- Appliance installation
- Electrical collegaments
- Gas connection
TYPE OF INSTALLATION SECOND UNI CIG 7129
As we go on we are going to show you the types of
installation second by the Uni Cig 7129 rule.
INTAKE AND EXHAUST TUBE FUMES ASSEM-
BLAGE
The intake & exhaust tubes can be
embedded
insi-
de the wall, or in
sight
, they have to be protected to
avoid, risk condition. To have the apparatus in sight
it exist a spacing bar so that you can see the tubes,
we recommend that the unloaded tubes (1) have
to have a good insulation using materials that
have also a resistant of more 200° C°
(ex. HT/-
Armaflex) of temperature. Realize the holes for
fastening the tubes, after establish the hangers
ʼ
length; insert it in the right position.
Before assembling the tubes verifying that the
Max tube length has been respected, even the
Max loaded loss provided
(See table).
(*) - Sum of the pressure leak both air suction and
gas exhaust pipes.
(**) - MAX two dye-cast curve: 1 for intake and 1 for
the unloaded.
1
1
Max single terminal tube length
Min comprehensive tube length
Loaded loss tube l 500 mm
Loaded loss tube l 1000 mm
Loaded loss single terminal
Loaded max loss permissible
MODEL
Faro
80
mm
mm
m
mm
Pa
Pa
Pa
Pa
Pa
54
110
10
0,6
1
1
0,6
19
Pa
5
Single terminal
Pa
1