The appliance is preset for the methane gas
(G20) following the technical label, but you can
change at GPL (G30/G31) with the transformation
that is furnished.
The transformation has to be done only by Technical
Service Assistance, the manufacturer or by authori-
zed persons even if appliance has been already
installed.
Shut down the appliance with the main button, and
then disconnect the electrical plug.
Proceed to the disassembling of the cover like
explained in the chapter assembling & disassembling
the cover.
Sequence apparitions
-To make the transformation you have to disconnect
the gas from the nipples R3/8 (1) that is on the cap.
- Take off the screws (2) then slip off the cap and the
burner group (3).
- Unscrew the screws (4) and the burner (5) and disk (8).
- Unscrew the 3 injectors (6) change them with the
new ones. Be real careful when you fasten the injec-
tor, check on the injector that it has the right values
as in the table.
-The injectors seal and the nipples 3/8”, are realized
mechanically so you don
ʼ
t need a gasket.
-Verifying that the values on the nozzles ore as in the
table below.
-Reassemble the cap with the burner, in the same
way that you dissembled don
ʼ
t forget the O-ring (7)
and disk (8) that goes around the cap.
-Proceed to the regulation as indicated in the Cap.
Regulation; verified the tubes gas connections capa-
city that goes from the gas valve to the burner.
-Change the gas labels; seal the parts that you made
the regulation, after the transformation. Don
ʼ
t forget
the old labels on the apparatus because it will cause
problems or danger.
GAS TRANSFORMATION
2
4
1
3
5
3
2
1
5
6
3
1
7
8
3
6
5
4
7
8
MODEL
faro
METHANE
1 , 3 0
L P G
0 , 7 4
mm
Ø
29
CUSTOMER SERVICE