32
CUSTOMER SERVICE
blow next to the injector; it will come out all the resi-
dues and the impurity caused from the burner.
Check all the injectors if are good.
Don
ʼ
t use metallic utensil.
Cleaning Electrode
The ignition electrode (1) and revelation (2) have to
be cleaned very carefully, after a period of time they
get fragile because of the work they have to perform.
- Unscrew the screws (3) and extract the electrode
group (1 o 2) using a little brush with metallic hair for
cleaning, after insert the electrode group (1 o 2) if
necessary exchange the seal gasket (4) be real
careful to not damage the electrode.
Pressure switch tubes
- Check that the tubes are cleaned.
- Air fan motor.
- Pressure switch unloaded fumes.
Replacing the Control board with Flame Control
To remove and refit the Flame Control board (1), fol-
low the instructions below:
- remove the board cover (3);
- loosen the retention screw (2) of the board cover;
- remove the connectors from their plugs;
- completely replace the electronic board, taking care
to reconnect all the wires properly.
4
1
2
3
1
2
3
COMPONENTS REPLACEMENT
Summary of Contents for faro
Page 1: ......