background image

EN30T2MOG0

50252 00911

02232 71913

7

0

4

2

Sticking coupon

Copia per / Copie pour / Copy for 

ITALKERO

ITALKERO S.r.l.

Via Lumumba, 2

Zona Industriale Torrazzi

41100 Modena (Italy)

Tel. ++39(0)59/2550711 - FAX ++39(0)59/250126

DITTA/MAISON/COMPANY

VIA/RUE/ADDRESS

N

CAP/CP/ZIP

LOC./LOC./CITY

PR./DEP./COUNTY

Ufficio

Bureau

Office

Casa

Habitation

House

Prima casa

Prem. habitation

First house

Seconda casa

Résidence secondaire

Second house

Serra/Serre

Exploitation Agricole Hothouse

Negozio / Laboratoire

Shop / Laboratory

Quanti sono installati?
Combien sont installés?
How many are installed?

DATA DI COLLAUDO
DATE D'ACHAT PAR L'UTILISATEUR FINAL.
PURCHASE DATE OF THE ENDUSER.

CERTIFICATO DI GARANZIA/CERTIFICAT DE GARANTIE/WARRANTY CERTIFICATE

LOCALIZZAZIONE e TIPOLOGIA / LOCALISATION et TYPOLOGIE

TIPOLOGY and LOCALIZATION

COGNOME/NOM/SURNAME

NOME/PRENOM/NAME

VIA/RUE/ADDRESS

N

CAP/CP/ZIP

LOC./LOC./CITY

PR./DEP./COUNTY

Firma leggibile Utente/Signature lisible de l'Utilisateur/User signature

L'

Utente

 dichiara di accettare tutte le condizioni di garanzia, di aver constatato il

buon funzionamento dell'apparecchio, di essere in possesso del libretto di istruzione,

di aver preso visione di quanto scritto e raccomandato sul presente certificato.

Garanzia: il consumatore è titolare di tutti i diritti di cui alla direttiva 99/44 CE.

Il testo completo delle condizioni di garanzia è riportato all’interno del Libretto di

Istruzioni, Uso e Manutenzione del prodotto.

IT

L'

Utilisateur

 déclare d'accepter toutes les conditions de garantie, d'avoir constaté

le bon fonctionnement de l'appareil, d'être en possession du manuel d'instructions,

d'avoir lu ce qui est écrit et recommandé sur le présent certificat.

Conditions de garantie: aux terms de la loi 99/44 CE.

Le texte complet des conditions de garantie se trouve à l'intérieur de la Notice

d'emploi et d'entretien du produit.

FR

The

 user 

declares that he accepts all the conditions of the guarantee, that he has

verified that the appliance works properly,

that he is in possession of the instruction manual and has read the terms and

recommendations on this certificate.

Warranty conditions: as by law 99/44 CE.

The warranty conditions are given in full inside the product's Instruction Manual.

UK

UTENTE

UTILISA

TEUR

USER

INST

ALLA

TORE

REVENDEUR

RET

AILER

XX00XXX000

00000 00000

00000 00000

0

0

0

0

Fabbricato da/Fabriqué par

Made by ITALKERO Srl

3525000010

La informiamo che, ai sensi della legge 675/96, i suoi dati, trattati elettronicamente e protetti, saranno da noi
utilizzati soltanto a fini promozionali. Lei potrà, in qualsiasi momento, richiederci l’aggiornamento o la cancellazione
scrivendo a Italkero Srl, via Lumumba 2 - 41100 Modena.

CENTRO

ASSISTENZA

TECNICA

DITTA/MAISON/COMPANY

VIA/RUE/ADDRESS

N

CAP/CP/ZIP

LOC./LOC./CITY

PR./DEP./COUNTY

Incolla qui il tagliando ADESIVO

Coller ici la vignette

Stick here the bar-code label

Chiesa
Eglise/Church

Officina
Atelier/Workshop

Altro/Autre/Another

Uno solo/Un seul/Only one

Più di uno/Plusieurs/More than one

Compilare tutto in STAMPATELLO
Remplir en caractères d'imprimerie
To write blockletters

n

Contratto di manutenzione programmata
Abonnement d’entretien annuel
Programmed maintenance contract

WARRANTY CONDITIONS

Every ITALKERO apparatus is supplied with a

warranty certificate, including the free coupon

and the first testing of the convector. The user

must be informed, that with this warranty you

have all the rights of a costumer, at second the

law 99/44 CE.

1) The warranty.

The warranty begins from the date that the

Technical service Assistance effectuates the testing,

if the convector is not tested the warranty decades.

The request of the testing has to be made by

Technical service Assistance in the 15 working

days from the date of the installation.  If the testing

is done after the start of the convector, the warranty

begins from the date of the deliver y.

2) Duration ITALKERO guarantees 10-year

duration on the heat exchanger & combustion

chamber.  All the other components have a

warranty of 24 months.

3) Term Decade denunciation obligation.

The owner has to denounce the malfunction of

the apparatus within 2 months from the

identification of it.

4) Warranty exclusion

The present warranty excludes damages & defects

coming from:

- Damage during the transport.

- Wrong installation

- Interventions by not authorized persons.

- Electric installation not in compliance with laws

and not proper gas usage

- Convector normal use

- Atmospheric agents

- Improper use

- All the cause above don’t depend from ITALKERO

The warranty comp rends the restoration

compliance of the apparatus. The warranty doesn’t

cover the damages that are done from people’s

are other things.

5) On line.

The warranties comprise the testing coupon with

out charging the user. The warranty certificate

has to be conserved for the Technical Service

Assistance. Whenever there are going to be any

original malfunction of the apparatus coming

from the projection, or the fabrication, the user

is going to have a free exchange of the apparatus

if all the precaution is been taken from an

installater. These intervenes are effectuated freely

for the user, for the elimination of the original

defects.  The material warranted is exclusively

prarty of ITALKERO and it has to be returned

with out any other damages, and provided with

the appositive label compile from Technical Centre

Assistance. Intervenes & substitution that are

caused from persons are other things the cost

price are excluded.

6) Territorial validity.

The warranty is valid only if the convector is

installed in the National Italian territory.

7) Acceptance.

The warranty is convaliteted only if the testing

coupon, is proprely completed in all his parts,

this has to be signed by a Centre Assistance and

from the User that going to conform and

understand all the above indicated clause.

00

ITALKERO

code

YEAR 2002

WEEK 23

271913

running

number

Product register format.

Product code

Product bar-code
Product bar-code

transcription

Register bar-code
Register bar-code

transcription

FAXSIMILE

FA

CSIMILE

example of W

orranty certificate

Summary of Contents for faro

Page 1: ......

Page 2: ...ERAL COMPLIANCE Our appliance are compliance at Gas directive 90 396 CEE Electromagnetic directive compatible 89 336 CEE Low tension directive 73 23 CEE 0694 RANGE F a r o MODEL CODE F R 7 0 R 2 M 0 0...

Page 3: ...l be long lasting reliable when it is installed and used properly manufacturer s guidelines are followed Good work and thanks The Manufacturer 3 GENERAL WARRANTY Provided that it is fitted in accordan...

Page 4: ...heated pag 19 54 mm pipes with single end piece pag 19 Diaphragms assemblage pag 23 Fitting the remote digital control pag 24 Electrical collegaments pag 25 Gas connection pag 26 CUSTOMER SERVICE Prel...

Page 5: ...nt to Art 17 of law no 46 90 and the instructions provided by the Manufacturer in the installer s booklet that accompa nies the product The appliance must be used as intended by the Manufacturer and f...

Page 6: ...f the apparatus The appliance is a gas radiator that heat up the atmosphere It has an intake of air that goes in the combustion chamber type C The appliance is made with an aluminium body that allows...

Page 7: ...ectrode 11 Pressure switch 12 Combustion chamber 13 Combustion fan 14 Garter spring 15 Power plug 16 Technical data plate 17 Gas valve 18 Gas tap 19 Manual control 20 Control unit 21 On Off switch 22...

Page 8: ...convector in box Terminal capacity reduction Qn Terminal power convector nomination Pn Terminal power convector reduction Pn Reduce nozzle pressure Main pressure nomination DESCRIPTION CODE 90 curve...

Page 9: ...T CN T1 VT TA BL WH RD SC EA ER EV1 F CL EV2 L N PS TL EP CVT SPLIT ROOM PROBE COMBUSTION FAN TANGENTIAL FAN CONNECTOR POWER TERMINAL TANGENTIAL FAN IGNITION TRANSFORMER BLUE WIRE WHITE WIRE RED WIRE...

Page 10: ...flashing Wireless default transmission about 2 5 minutes 4e GREEN Led flashing Wireless data transmission by the change of any parameter 5 Wireless On button switch press and hold 2 seconds LED 4 star...

Page 11: ...sists of Q ty Description 1 90 curve in cast aluminium 1 90 curve in aluminium 1 Gas tap with connections 2 Pipes 54 mm L 500 mm 1 Single end piece with integrated rosette 4 6 mm screw anchors for fas...

Page 12: ...fastened to a wall as an extension of same B between two perpendicular walls C in the middle of a wall D in the centre of an environment 12 INSTALLER mm 2157 mm 680 mm 312 kg 58 faro Height B Width C...

Page 13: ...nce tubes there are mate rials that can support the heath second check if the wall is made of the right material and can support the appliance weight Verified if around the exhaust fumes tubes there i...

Page 14: ...bar so that you can see the tubes we recommend that the unloaded tubes 1 have to have a good insulation using materials that have also a resistant of more 200 C ex HT Armaflex of temperature Realize t...

Page 15: ...he extraction pipe that runs along the entire side upright of the appliance During the drilling operations be very careful not to damage drill the gas pipes and wiring harnes ses passing along the sid...

Page 16: ...ng the weight of the appliance taking into account above all the material from which the wall is made fasten the appliance in the desired position Use the anchors most suitable for suppor ting the wei...

Page 17: ...on regulate the overhang of the L shaped plate 1 with respect to the bracket 4 then tighten the screw 2 well so as to keep the panel up against the frame causing it to adhere properly on the seal 6 on...

Page 18: ...t the pipes and any corner curves in the wall without the single end piece position the extraction exhaust pipes flush with the outer wall being careful that the exhaust pipe 1 is always higher than t...

Page 19: ...an be summed up in the three examples described in this chapter Before assembling the Pipes check complian ce with MAX pipe length and MAX accepta ble flow resistance see Chart Sum of the pressure lea...

Page 20: ...ted by two kinds of tubes 54 mm With 54 mm tubes Adapt the length tube to the wall space so it increases 25 mm then cut it the adapter connection unit is already fitted on the top part of the applianc...

Page 21: ...adapter preparation is effected by two kinds of tubes 54 mm With 54 mm tubes Adapt the length tube to the wall space so it increases 25 mm then cut it the adapter connection unit is already fitted on...

Page 22: ...stant to temperatures above 200 C eg HT Armaflex Adapter pipe connection unit with 54 mm pipes Adapt the length of the fume exhaust pipe to the thickness of the wall increased by 25 mm cutting the ex...

Page 23: ...g HT Armaflex Chimneypot assemblage To assemble the chimneypot on the unloaded intake tubes use the clamp 1 and the 2 safety screw The chimneypot application has to satisfy the fol lowing requirement...

Page 24: ...the limit of the range of action C If the LED does not flash you are outside the range of action mark the position of the fastening holes on the wall and drill fit the screw anchors and screws most s...

Page 25: ...socket provided and making an EARTH connection that is 2 cm longer than the PHASE and NEUTRAL leads Connect the other end of the cable to a socket or omnipolar switch in conformity with CEI standards...

Page 26: ...to realize a good ground connection and to respect the neutral phase During the first starting you might verify vapour and irritating smells not dangerous To avoid these discomfort we advice to aerat...

Page 27: ...ature In case of malfunctions in startup procedure or ope ration the appliance STOPS and the relevant unblock signal lights up on the display Reset the appliance by keeping the unblock button pressed...

Page 28: ...ed that the gas pressures are as under the Table The gas pressure value has to be as in the table The apparatus execute a stop and next restart Operating from the main control panel Operate on the atm...

Page 29: ...urner 5 and disk 8 Unscrew the 3 injectors 6 change them with the new ones Be real careful when you fasten the injec tor check on the injector that it has the right values as in the table The injector...

Page 30: ...nimum pressure are as spe cified in the table To make a regulation operate on the screw that is on the modulator body 4 Rotating the regulator screw 3 clockwise the pressure decrease rotating counter...

Page 31: ...h to the off position Close the gas tap Wait that the appliance gets cold completely Cover clean The only cleaning that is required by the owner involves removing the cover and wiping it clean the dus...

Page 32: ...ittle brush with metallic hair for cleaning after insert the electrode group 1 o 2 if necessary exchange the seal gasket 4 be real careful to not damage the electrode Pressure switch tubes Check that...

Page 33: ...mbustion chamber 6 Disassemble a half sleeve 4 with the clamp 2 and after the fan 5 Unscrew the screw away the fan frame complete of curves connector 7 and ant vibration gasket 8 Disassemble the curve...

Page 34: ...trips if the convection fan is not working properly or anomalous overheating occurs and or the outflowing air temperature reaches over 107 C disengaging the burner closing the gas valve and stopping...

Page 35: ...the Pressure switch Extract the pressure switch 1 from support 2 Take off the tubes 3 4 and the electrical connec tors from the pressure switch Unscrew the stirrup support fixing screw 2 separa ting t...

Page 36: ...essure Set correct pressures Thermostat fails to engage Adjust the thermostat Burnt out fuse Replace Control board faulty Replace High room temperature Room thermostat set too high Air in gas pipes Bl...

Page 37: ...nd regulate the gas replace Power of appliance not enough for installation premises Replace the appliance with a more powerful one Faulty control board Replace The tangential fan does not work Faulty...

Page 38: ...Seller Street tel Sir Installer Street tel Sir Technical Service Assistance Street tel Date Intervention USEFUL INFORMATION 38 CUSTOMER SERVICE...

Page 39: ...er Uno solo Un seul Only one Pi di uno Plusieurs More than one Compilare tutto in STAMPATELLO Remplir en caract res d imprimerie To write blockletters n Contratto di manutenzione programmata Abonnemen...

Page 40: ...3520300031 Rev 2...

Reviews: