ISG18GFP USER MANUAL, GENERAL, SECTION G
UM-G-iSG18GFP-4.5.06.1-EN.docx
8
© 2020 IS5 COMMUNICATIONS INC. ALL RIGHTS RESERVED
3.3.2 Wiring AC Input Voltage Connector
For an AC product option, there is a single input connector
Use a brown wire for the Line (Phase) conductor, a green/yellow for the grounding, and a Blue wire for the neutral
conductor. Use 18AWG (1mm2) wire with insulated ferrules.
3.3.3 Power Budget
Please refer to the iSG18GFP installation guide for complete breakdown of power consumption per product group
and recommended upstream fuse protection.
Following table details power consumption for any hardware variants (with cellular and serial interfaces).
Table 3 – Power Consumption Details
Unit Power feed
Max Power [Watt]
Version without POE ports
Max Power [Watt] Version with POE ports
12 VDC
20
90
24 VDC
20
130
48 VDC
20
140
110 VDC
20
140
110 VAC
30
140
220 VAC
30
140