Connecting Leads to a Spring Clamp Terminal Block
The ioibox units come with terminal block connectors. Each connector is for terminating wires and
then plugging the connector into either the Relay Output or Alarm Inputs of the ioibox unit.
To Connect a Wire to the Spring Clamp Terminal Block
Spring Clamp Terminal Blocks
1. With a small screwdriver, press in and hold the orange spring-clamp button next to the
female outlet where the wire will be inserted.
2. Insert the wire in the female outlet. Note the wire end should be stripped of insulation.
3. Release the orange spring-clamp button.
Connecting a Wire to a Terminal Block
59