Pulsar extractor fan
•
Installation and operating instructions
2 Sensor-controlled, without continuos ventilation:
• Factory setting to ensure ventilation as required.
• The extractor fan is switched on and off automatically when the humidity or lighting changes.
3 Use as a wall-vent fan
• This setting must be selected via the inVENTer Mobile app.
• Suitable for ventilation of adjacent rooms.
• The extractor fan is switched on/off based on the temperature, the light and humidity sensors are inactive.
4 Switch-controlled, without run-on function:
Wiring diagrams 12 V DC connection
1 Sensor-controlled, with continuous
ventilation:
• This setting must be selected via the
inVENTer Mobile app.
• Continuous ventilation with a flow rate of
30 m³/h.
• Increases the fan power with elevated
humidity or due to lighting changes.
Figure 10: Wiring diagram for flush-mounted PSU NT16 and Pulsar extractor fan 12 V DC
Versions 1 to 3 (sensor-controlled and use as wall-vent fan)
• This setting must be selected via the
inVENTer Mobile app.
• The extractor fan is switched on and off
by means of a manual, external S switch.
• The sensors are deactivated.
ELECTRICAL CONNECTION
TIP:
The S1 switch integrated into the Pulsar extractor fan does not work with a 12 V DC connection.
AC 100
−
240 V
DC 12 V
S1
M
T
L
N
AC 230 V
L
N
DC
AC
Figure 11: Wiring diagram for flush-mounted PSU NT16 and Pulsar extractor fan 12 V DC
Version 4 (switch-controlled)
AC 100
−
240 V
DC 12 V
S1
M
T
L
N
S
AC 230 V
L
N
DC
AC